Model UT60F/G: OPERATING MANUAL
Measurement Operation(8)
Note
l In a circuit, a good diode should still produce a forward
voltage drop reading of 0.5V to 0.8V; however, the
reverse voltage drop reading can vary depending
on the resistance of other pathways between the
probe tips.
l Connect the test leads to the proper terminals as
said above to avoid error display.
l The LCD will display OL indicating either open circuit
or wrong polarity connection.
l The unit of diode is volt (V), displaying the positive-
connection voltage-drop value.
l Diode test has only auto range mode, open circuit
voltage approximate 3V.
l When diode testing has been completed, disconnect
the connection between the testing leads and the
circuit under test and remove testing leads from the
input terminals.
F. Testing for Continuity
( figure 8)
(see figure 8)
Select
red
24