Download Print this page
UNI-T ut60c Operating Manual
Hide thumbs Also See for ut60c:

Advertisement

Quick Links

Model UT60B/C/E: OPERATING MANUAL
General Specifications
l Maximum Voltage between
any Terminals and Grounding:
l
Fused Protection for
UT60B: Glass fuse, 0.5A, 250V, fast type, 5x20mm.
l
Fused Protection for
UT60C/E:
l
Fused Protection for 10AInput Terminal:
UT60B/C/E: Glass fuse, 10A, 250V, fast type, 5x20mm.
l Maximum Display: Digital: 3999
l Measurement Speed: Updates 3 times/second.
l
Temperature: Operating : 0
l Relative Humidity:
l Altitude: Operating: 2000 m.
Storage : 10000 m.
l Battery Type: One piece of 9V (NEDA1604 or 6F22 or
006P).
l Battery Deficiency: Display
l Dimensions (HxWxL): 177 x 85 x 40 mm.
l Weight: Approximate 300g (battery included).
l Safety/Compliances: IEC61010 CAT.III 1000V,
CAT.IV 600V overvoltage and double insulation standard.
l Certifications:
Glass fuse, 0.5A, 250V, fast type, 5x20mm.
Storage : -10
:
75% @ 0
,
UL & CUL
26
1000V.
Input Terminal: Model
Input Terminal: Model
o
o
o
C~40
C (32
F ~104
o
o
o
C~50
C (14
F~122
o
o
C - 30
C; 50% @ 31
o
F).
o
F).
o
o
C - 40
C;

Advertisement

loading
Need help?

Need help?

Do you have a question about the ut60c and is the answer not in the manual?

Questions and answers

Summary of Contents for UNI-T ut60c

  • Page 1 Input Terminal: Model UT60B: Glass fuse, 0.5A, 250V, fast type, 5x20mm. Fused Protection for Input Terminal: Model UT60C/E: Glass fuse, 0.5A, 250V, fast type, 5x20mm. Fused Protection for 10AInput Terminal: UT60B/C/E: Glass fuse, 10A, 250V, fast type, 5x20mm. l Maximum Display: Digital: 3999 l Measurement Speed: Updates 3 times/second.
  • Page 2: Accuracy Specifications

    750V AC rms 100mV 400V continuous. 750V (1.2%+5) Remarks: l Input impedance 10M l Model UT60B/UT60C: displays effective value of sine wave (mean value response). Model UT60E: displays true rms value. l Frequency response 40Hz~400Hz. C. Resistance Overload Range Resolution...
  • Page 3 Model UT60B/C/E: OPERATING MANUAL Accuracy Specifications (2) D Continuity Test Overload Range Resolution Accuracy Protection 1000Vp 400.0 Approximate 100 Remarks: l Buzzer beeps continuously. l Open circuit voltage approximate 0.45V. E. Diode Test Range Resolution Overload Protection Diode 1000Vp Remarks: l Open circuit voltage approximate 1.48V.
  • Page 4 Model UT60B/C/E: OPERATING MANUAL Accuracy Specifications (3) H.Temperature (Model UT60C/UT60E) Overload Protection: Glass fuse 0.5A, 250V, fast type, 5x20mm. I. DC Current 400 A 0.1 A 0.5A, 250V, fast type Glass fuse, 5x20 mm. 10A, 250V, fast type Glass fuse, 5x20 mm.
  • Page 5 Glass fuse, 5x20 mm. 10A, 250V, fast type Glass fuse, 5x20 mm. Remarks: Model UT60B/UT60C : displays effective value of sine wave (mean value response). Model UT60E : displays true rms value. l 4A & 10A Range: For continuous measurement 10 seconds and interval not less than 15 minutes.

This manual is also suitable for: