Measurement Operation(13)
J. Temperature Measurement
Warning
To avoid harms to you, please do not attempt to input
voltages higher than 60V DC or 30V rms AC.
The temperature measurement range is -40
To measure temperature, connect the Meter as follows:
1.
Set the rotary switch to
temperature.
2.
Insert the multi-purpose socket into the Meter as the
figure 10.
3.
Insert the point contact temperature probe into the
multi-purpose socket
4.
Place the temperature probe to the object being
measured.
The measured value shows on the display after
several seconds.
Note
l Place the Meter in an environment of 18~23
otherwise false reading may be obtained especially
in testing low temperature.
l When temperature measurement has been completed,
remove the temperature probe away from the multi-
purpose socket, and remove the multi-purpose socket
away from the Meter.