Temperature Measurement(Ut208A Only) - UNI-T UT208A Operating Manual

Digital clamp multimeter
Hide thumbs Also See for UT208A:
Table of Contents

Advertisement

UT207A/208A/209A Operating Manual
G. Temperature Measurement (UT208A only, see figure 9)
To measure temperature measurement, connect the Meter as follows:
1. Insert the red temperature probe into the VΩHz terminal and the black
temperature probe into the COM terminal.
2. Set the rotary switch to ℃ measurement mode.
3. Place the temperature probe to the object being measured. The measured
value shows on the display.
Note
● When the Meter is at ℃ range, display "OL" to remind user to insert
temperature probe.
● The Meter automatically displays the room temperature when the
temperature probe is inserted but without any input.
● The included point contact temperature probe can only be used up to 230℃.
For any measurement is higher than that, the rod type temperature probe
must be used.
● When the temperature measurement has been completed, disconnect
the connection between the temperature probe and the object under test,
and remove the temperature probe away from the input terminals of the
Meter.
31