UT207A/208A/209A Operating Manual
Accurate Specifications
Accuracy: ±(a% reading + b digits), guarantee for 1 year.
Operating temperature: 23℃±5℃
Relative humidity: ≤80%R.H
Temperature coefficient: 0.1×(specified accuracy)/1℃
A. DC Voltage
Range
Resolution
400mV
0.1mV
4V
0.001mV
40V
0.01V
400V
0.1V
1000V
1V
Remark: Input Impedance: 10MΩ.
Accuracy
±(0.8%+3)
±(0.8%+1)
±(1.0%+3)
37
Overload protection
DC1000V/AC750V