Dc Current; Ac Current - UNI-T UT60D Operating Manual

Table of Contents

Advertisement

Accuracy Specifications (4)
F.

DC Current

Range
Resolution
340 A
0.1 A
3400 A
1 A
34mA
10 A
340mA
100 A
10A
10mA
Remark:
l
10A Range:
For continuous measurement 10 seconds and
interval time between 2 measurements greater than
15 minutes.
G. AC Current
Range
Resolution
340 A
0.1 A
3400 A
1 A
34mA
10 A
340mA
100 A
10A
10mA
Remarks:
l
Frequency response 40Hz ~ 1kHz.
l
Displays effective value of sine wave (mean value
response).
l
10A Range:
For continuous measurement 10 seconds and
interval time between 2 measurements greater than
15 minutes.
Model UT60D: OPERATING MANUAL
Accuracy
Overload Protection
0.5A, 250V, fast type
(1.2%+2)
Glass fuse, 5x20 mm.
10A, 250V, fast type
(1.5%+2)
Glass fuse, 5x20 mm.
Accuracy
Overload Protection
0.5A, 250V, fast type
(1.5%+5)
Glass fuse, 5x20 mm.
10A, 250V, fast type
(2.5%+5)
Glass fuse, 5x20 mm.