Minimum Flow Adjustment For The Oven And Grill Burners - Baumatic BCG520SL Instruction Manual

50 cm twin cavity gas slot-in cooker
Hide thumbs Also See for BCG520SL:
Table of Contents

Advertisement

o Unscrew the injector and replace it with the required injector for
the new gas supply according to the table below.
Burner Type
Oven Burner
Grill Burner
o After changing the injectors YOU MUST change the minimum
flow rate.

Minimum flow adjustment for the oven and grill burners

All work must be carried out by a GASSAFE
registered engineer.
o In order to access the adjusting screws to change the minimum
flow rate of the grill and oven burners, you need to remove the
hob top and control panel.
o To take the hob top off, remove the screws fixing the hob to the
cooker.
o When all the screws have been removed, slide the hob from the
back to the front and lift it off the support brackets which hold
the hob down at the front of the cooker.
Gas Type
Pressure
Mbar
Natural
20
Gas
Liquid Gas 28..30/37
Natural
20
Gas
Liquid Gas 28..30/37
35
Injector
Marking
(1/100mm)
Max Min
1.05
2.1
0.72
1.00
1.8
0.66
Power
(Kw)
0.8
0.6

Advertisement