Gas Adjustment (Conversion To Lpg For The Hob Top) - Baumatic BCG520SL Instruction Manual

50 cm twin cavity gas slot-in cooker
Hide thumbs Also See for BCG520SL:
Table of Contents

Advertisement

Gas adjustment (Conversion to LPG for the hob top)

All work must be carried out by a GASSAFE
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o Remove the pan supports, burner cap and burner rings.
o Unscrew the injector and replace it with the required injector for
the new gas supply according to the table below.
Burner Type
Auxiliary (Small)
Semi Rapid
(Medium)
Rapid (Large)
o When all four jets have been replaced, reassemble all the
burners carefully, taking particular care to make sure that the
burners and burner caps are aligned properly.
o After changing the injectors YOU MUST change the minimum
flow rate.
Gas Type Pressure
Mbar
Natural
20
Gas
Liquid Gas 28..30/37
Natural
20
Gas
Liquid Gas 28..30/37
Natural
20
Gas
Liquid Gas 28..30/37
32
Injector
Marking
(1/100mm)
Max Min
72
50
97
1.75 0.6
65
115
85
Power
(Kw)
1
0.3
3
1