2.2. ASSEMBLY

2.2.1. EXTERNAL POWER SOURCE

WARNING
When the unit is to be powered with external sources, first make
sure the batteries have been taken out.
As an external power source, a standard network controller with
outer voltage of 6V and current of over 0.5A can be applied. To con-
nect an external source recommend to use a 6mm standard double-
pole socket in the way the positive contact is the central contact.
Use both the video or PC cable to connect an external 6 VDC/ 1 A
power supply to the OTS.
Connect an external power supply to the monocular as follows:
1. Remove the batteries.
2. Remove the protective cap from the monocular output con-
nector socket.
3. Attach the video/PC cable to the output connector socket.
4. Attach the power jack socket of the cable to a 6 VDC/ 1 A
power supply.
NOTES
1.
The external power supply plug must have a 6 mm OD con-
tact with center pin positive.
2.
Avoid a sudden removal of power source: use the power
button «ON/OFF» to turn the monocular off before you remove
batteries or disconnect external power supply.
3.
Replace the protective cap on the monocular output con-
nector socket after disconnecting the cable.
2.2.2. VIDEO OUTPUT
The OTS incorporates a sealed Connector used for video trans-
mission and to connect external power sources. Video Cable at-
taches the scope to the video facilities for video recording or video