Range Specifications
Function
Range
DC Voltage
200mV
(V DC)
2000mV
20V
200V
600V
AC Voltage
200V
(VAC) 50/60Hz
600V
DC Current
2000µA
(A DC)
20mA
200mA
10A
Resistance
200Ω
2000Ω
20kΩ
200kΩ
2000kΩ
Battery Test
9V
1.5V
Notes:
Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
o
Accuracy is stated at 65
F to 83
Resolution
Accuracy
0.1mV
±(0.5% reading + 2 digits)
1mV
0.01V
0.1V
±(0.8% reading + 2 digits)
1V
0.1V
±(1.2% reading + 10 digits)
1V
±(2.0% reading + 4 digits)
1µA
±(1.0% reading + 2 digits)
10µA
100µA
±(1.5% reading + 2 digits)
10mA
±(2.0% reading + 2 digits)
0.1Ω
1Ω
±(0.8% reading + 2 digits)
0.01kΩ
0.1kΩ
±(1.0% reading + 2 digits)
1kΩ
10mV
±(1.0% reading + 2 digits)
10mV
o
o
o
F (18
C to 28
C) and less than 75% RH.
9