RANGE SPECIFICATIONS

Function
Range
DC Voltage
400mV
(V DC)
4V
40V
400V
600V
AC Voltage
400mV
(V AC)
4V
(50/60Hz)
40V
400V
600V
DC Current
400μA
(A DC)
4000μA
40mA
400mA
10A
AC Current
400μA
(A AC)
4000μA
(50/60Hz)
40mA
400mA
10A
Resistance
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
Capacitance
4.000nF
40.00nF
400.0nF
4.000uF
40.00uF
100.0uF
Notes:
Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
Resolution
Accuracy
0.1mV
±(0.5% reading + 2 digits)
1mV
±(1.2% reading + 2 digits)
10mV
100mV
±(1.5% reading + 2 digits)
1V
0.1mV
±(1.5% reading + 15 digits)
1mV
±(1.2% reading + 3 digits)
10mV
±(1.5% reading + 3 digits)
100mV
1V
±(2.0% reading + 4 digits)
±(1.0% reading + 3 digits)
0.1μA
1μA
±(1.5% reading + 3 digits)
10uA
100uA
10A
±(2.5% reading + 5 digits)
±(1.5% reading + 5 digits)
0.1μA
1μA
±(1.8% reading + 5 digits)
10uA
100uA
±(3.0% reading + 7 digits)
10A
±(1.2% reading + 4 digits)
0.1Ω
±(1.0% reading + 2 digits)
10Ω
±(1.2% reading + 2 digits)
100Ω
1kΩ
±(2.0% reading + 3 digits)
10kΩ
1pF
±(5.0% reading + 50 digits)
±(5.0% reading + 7 digits)
10pF
0.1nF
±(3.0% reading + 5 digits)
1nF
10nF
0.1uF
±(5.0% reading + 5 digits)