E&M Delay Start Signaling Configuration Commands; Set Port Port Emd In_Delay_Max; Set Port Port Emd In_Delay_Min; Set Port Port Emd In_Digit_Ign - Planet VIP-000 User Manual

Internet telephone gateway
Table of Contents

Advertisement

VIP User's Manual
200
E&M Delay Start Signaling Configuration Commands
The E&M delay start signaling configuration commands are used to define parameters specific to
E&M delay start interface. These commands apply to E&M Delay Start signaling protocol only.

set port port emd in_delay_max

This command is used to set the maximum duration of the delay signal response to the Seize De-
tect (of incoming calls) on the M-lead.
set port port emd in_delay_max milliseconds
Syntax description
milliseconds
Default
2500

set port port emd in_delay_min

This command is used to set the minimum duration of the delay signal response to the seize detect
(of incoming calls) on the M-lead.
set port port emd in_delay_min milliseconds
Syntax description
milliseconds
Default
200

set port port emd in_digit_ign

This command is used to set the period of time, after completing the delay signal, before the digits
will be accepted on incoming calls.
set port port emd in_digit_ign milliseconds
Syntax description
milliseconds
Default
30
Command Line Interface
Time in milliseconds, ranging from 0 to 65535.
Time in milliseconds, ranging from 0 to 65535.
Time in milliseconds, ranging from 0 to 65535.
87

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vip-200Vip-400Vip-400fsVip-400fo

Table of Contents