1 2 0 5 P ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 1 1 3 0 0 1 U A EMISSION REQUIREMENTS FCC CLASS A Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC rules.
The use of two modems is eliminated with a resulting cost savings to the user. The 1205P (CTS ME-V.35) complies with the CCITT V.35 balanced interface specification. Two 34 pin V.35 (MR-34) connectors are provided to interface to the V.35 terminals.
15 class A emissions approvals insure the Modem Eliminator will not interfere with any of the other equipment in your data center. The Model 1205P Serieshas been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation.
NSTALLATION Power Connection Before connecting the 1205P (CTS ME-V.35) to a AC power source the top cover must be installed and secured with the supplied #8-32 screws. The unit is supplied with a 110/ 220VAC voltage switch, turn the switch with a...
V.35 (MR-34) connectors should be used to connect the two terminals to the 1205P (CTS ME-V.35). Set the switches and Jumpers to match the required configuration using the descriptions in this chapter and the strapping guide in the appendix.
1 2 0 5 P ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 1 1 3 0 0 1 U A CTS Delay, Port 2 (SW2-4,5) SW2 position 4 and 5 selects RTS to CTS delay for the terminal connected to PORT 2. RTS (pin 4) from PORT 2 is looped back to CTS (pin 5) through the delay circuitry.
1 2 0 5 P ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 1 1 3 0 0 1 U A Clock Source, Port 2 (JP5) Port 1 clock selection is accomplished via JP5. To select the internal baud rate generator as the clock source install the jumper on the side marked INT. To use an external source provided on Port 1 Pins W &...
1 2 0 5 P ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 1 1 3 0 0 1 U A High Speed Option Rates (JP7,JP8,JP9,JP10) If the high speed option is installed the following rates can be utilized by setting SW1 positions 1 through 4 to ON: JP10 Installed JP7, JP8 &...
1 2 0 5 P ATTON LECTRONICS NSTALLATION PERATIONS ANUAL 1 1 3 0 0 1 U A PPENDIX Technical Specifications Application Data Rates CTS, RTS, DCD, TT, RT Interconnect two V.35 terminal 4.8K, 9.6K, 14.4K, 19.2K, type devices 28.8K, 38.4K. 48K, 56K, Channel Interface 57.6K, 64K, 72K, 128K, 192K, Capacity...
Page 13
JP6 - Port 1 Clk Source Install Only One Jumper to Select the Required Rate Power JP5 - Port 2 Clk Source Port 2 Baud Rate Select SW1 Speed HS Option CGND 768K Port 1 CTS Delay SW2 384K De lay DGND 192K Constant...