4.2 CONFIGURING THE HARDWARE DIP SWITCHES

The Model 1088 has two sets of eight DIP switches, which allow
configuration for a wide variety of applications. This section describes
switch locations and explains all settings.
The 16 external switches are grouped into two eight-switch sets,
and are externally accessible from the underside of the Model 1088, as
shown in Figure 4, below.
ON
OFF
Figure 4. Underside of Model 1088, showing location of DIP switches
The two sets of DIP switches on the underside of the Model 1088
will be referred to in this manual as S2 and S3. As Figure 5 shows,
the orientation of all DIP switches is the same with respect to "ON" and
"OFF" positions.
ON
Figure 5. Close Up of Configuration Switches (all sets are identical in appearance)
9
FRONT
S2
S3
REAR
OFF
4.2.1 Configuration DIP Switch Set "S2"
The only setting for S2 is for Clocking Mode between Model
1088s. All other switches are reserved for factory usage and must
remain in the default configuration. Default settings are shown in the
table below.
S2 SUMMARY TABLE
Position
Function
S2-1
Reserved
S2-2
Reserved
S2-3
Reserved
S2-4
Reserved
S2-5
Reserved
S2-6
Clock Mode
S2-7
Clock Mode
S2-8
Reserved
Switch S2-1, S2-2, S2-3, S2-4, S2-5 and S2-8:
Switches S2-1, S2-2, S2-3, S2-4, S2-5 and S2-8 are reserved for fac-
tory use and must remain in the factory default settings as shown in
the table above.
Switches S2-6 and S2-7: Clock Mode
Use Switches S2-6 and S2-7 to configure internal, or receive
recover (clocking derived from the remote Model 1088 across the DSL
span) settings. One Model 1088 (typically the CO, or "Central Office"
unit) will be set for Internal Clock. The remote Model 1088 (typically
the CP, or Customer Premises unit) will be set for Receive Recover
clocking. The table below shows the clock mode settings.
CO/CP
Unit
S2-6
S2-7
Clock Mode
CO
On
On
Internal
CP
On
Off
Receive Recover receives its timing
10
Factory Default
Off
Off
Off
Off
Off
Receive
On
Recover
Off
Off
Description
Model 1088 gener-
ates internal, crystal
controlled timing.
Model 1088
from the CO unit
over the DSL span.

Advertisement