Download  Print this page

Patton electronics 1089/I User Manual

10baset hdsl rocket
Hide thumbs

Advertisement

10BaseT HDSL Rocket
Part# 07M1089/I-A
SALES OFFICE
Doc# 032071UA
(301)975-1000
Revised 12/7/99
TECHNICAL SUPPORT
(301)975-1007
An ISO-9001
http://www.patton.com
Certified
Company

Advertisement

loading

  Also See for Patton electronics 1089/I

  Related Manuals for Patton electronics 1089/I

  Summary of Contents for Patton electronics 1089/I

  • Page 1 10BaseT HDSL Rocket Part# 07M1089/I-A SALES OFFICE Doc# 032071UA (301)975-1000 Revised 12/7/99 TECHNICAL SUPPORT (301)975-1007 An ISO-9001 http://www.patton.com Certified Company...
  • Page 2: Radio And Tv Interference

    Section 1.0 Warranty Information ...2 1.1 Radio and TV Interference 1.2. CE Notice 1.3 Service 2.0 General Information...4 2.1 Features 2.2 Description 3.0 Configuration ...5 3.1 Configuring the Hardware DIP Switches 3.1.1 Configuration DIP Switch Set “S2” 3.1.2 Configuration DIP Switch Set “S3” 4.0 Installation ...9 4.1 Connecting the DSL Interface 4.2 Connecting the 10BaseT Ethernet Port to PC (DTE)
  • Page 3 1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at: tel: (301)975-1007...
  • Page 4: Configuring The Hardware Dip Switches

    The Model 1089 has two sets of eight DIP switches, which allow configuration for a wide variety of applications. This section describes switch locations and explains all settings. 3.1 CONFIGURING THE HARDWARE DIP SWITCHES The 16 external switches are grouped into two eight-switch sets, and are externally accessible from the underside of the Model 1089, as shown in Figure 1, below).
  • Page 5 3.1.2 Configuration Switch Set “S3” Use the DIP Switches in Switch S3 to set the DTE Rate (for LAN Bandwidth Allocation), the transmit data sampling point and to reset the unit to its software default settings. The following table summa- rizes default positions of DIP Switch S3.
  • Page 6: Connecting The Dsl Interface

    When the Model 1089 has been properly configured, it may be connected to the DSL twisted pair interface, the 10BaseT Ethernet Interface, and the power source. This section describes these connec- tions. 10BaseT Interface Figure 3. Model 1089 Rear Panel 4.1 CONNECTING THE DSL INTERFACE The Model 1089 supports communication between 10BaseT Hubs or Workstations at distances to 5 miles (8 km) over 24 AWG (.5mm)
  • Page 7: Power Connection

    The 36-60 VDC DC to DC adapter supplied with the DC version of the Model 1089 plugs in a DC source (nominal 48VDC) and plugs into the barrel power supply jack on the rear of the 1089/I. Please refer to Figure 5, below, to make the proper connection.
  • Page 8: Test Modes

    7 pulses = WAN receive frame(s) aborted 8 pulses = Detected WAN receive frame(s) with 9 pulses = Detected LAN receive frame(s) too large 10 pulses = Detected LAN receive frame(s) not octet aligned 11 pulses = Detected LAN receive frame(s) with bad 10BT Link (Active Green) Solid green indicates that the 10BaseT Ethernet interface has detected a valid...
  • Page 9 (because it originates after the framer) and is intended to be evaluated only by another Processor. If the units are transmitting data and the pattern generator is enabled on one end of the link, the far end will begin receiving unframed packets and assume that the line has gone down.
  • Page 10 5.3.2 Loops and Patterns The following section describes the Remote Loopback/BER test modes. Remote Digital When Remote Loop/511 or Remote Loop/511/E is enabled via the front panel switch, the Remote unit’s Restart Timer is set to one minute. This is because when the 511/511E generator is initiated on the local unit, the Remote framer begins seeing unframed pack- ets.
  • Page 11 6 Rx Data + pins 4, 5, 7, 8 no connection Patton Electronics Model # Description 1089/I ...10BaseT HDSL Rocket (CAP) 080551 ...120V Power Supply 080552 ...230V Power Supply 48V-PSM...DC Power Supply Module 08055DCUI ...100-240VAC (+5V ±5% reg. DC/2A) Universal Input Adapter 0805EUR ...European Power Cord CEE 7 (“A”)
  • Page 12 Transmission Distance - Patton NetLink HDSL Model 1089 No Cross Talk Line Rate DTE Rates 26 AWG (0.4mm) 24 AWG (0.5mm) kbps feet miles km 64, 128 20700 6.2 24500 192, 256 17400 5.2 24200 320, 384 15100 4.6 22600 448, 512 14900 4.4 21000...