48
The file name format usually is: SN_CH+channel number+time
Y+M+D+H+M+S. In the file name, the YDM format is the same as what you
set in general interface (Main MenuSettingGeneral). The file
extension name is ".dav". You can visit our website to view listed CD-ROM
brands.
Tips:
During the backup process, you can click ESC to exit the current
interface for other operations. The system will not terminate the backup
process.
When you click Stop during the burning process, backup
Note
will be stopped immediately, and some selected files may
not be saved correctly in the device.
The operations described here are mainly based on
PELCO-D protocol for Honeywell HSD-261/HSD-
Note
361/HSPT-120 speed dome. For other protocols, there
might be a little difference.
Please follow the procedures below to go on cable connection
Connect the dome RS485 port to DVR 485 port.
Connect the dome video output cable to DVR video input port.
Connect the power adapter to the dome.