Trane CVGF-SVN02B-E4 Installation Manual page 5

Gear-driven centrifugal water-cooled liquid chillers, unit model cvgf 400-1000 ton units (50 and 60 hz)

Advertisement

Literature Change History
CVGF-SVX001-E4 (July 2000)
This manual describes the
installation, operation, and
maintenance of CVGF units.
CVGF-SVN02A-E4 (2002)
Replaces CVGF-SVX001-E4.
About this Manual
This manual describes proper
installation of Model CVGF, 50 Hz
and 60 Hz chillers with the Tracer
CH530 Controls platform. See
Figures 2 and 3 for an illustration
of a CVGF Centrifugal Chiller
with the Tracer CH530 Unit
Control Panel.
These chillers are equipped with
microcomputer-based control
systems. A careful review of this
information along with the
submittal package provided for
the unit will assure that the
chiller is correctly installed.
Unit Identification -
Nameplates
When the unit arrives, compare
all nameplate data with order,
submittal and shipping
information. A typical unit
nameplate is shown in Figure 1.
CVGF-SVN02B-E4
General
Information
Figure 1. Typical unit nameplate
MODEL: CVGF500
MODEL NO:
CVGF0500RA0U33809405C1B5C1C23A1A201E3AA0
SERIAL NO:
ELECTRICAL CHARACTERISTICS:
RATED VOLTAGE:
NAMEPLATE NMKW:
VOLTAGE UTILIZATION RANGE:
MINIMUM CIRCUIT AMPACITY:
MAXIMUM FUSE:
MAXIMUM CIRCUIT BREAKER
MAXIMUM OVERLOAD TRIP: 617 AMPS
LRAD
COMPRESSOR MOTOR
OIL PUMP MOTOR
OIL TANK HEATER
CONTROL CIRCUIT
WHEN MOTOR CONTROLLER PROVIDED BY OTHERS
TRANE ENGINEERING SPEC. S6516-0360 APPLIES
GENERAL CHARACTERISTICS:
REFRIGERANT SYSTEM
TO BE FIELD CHARGED
WITH 340 KG OF R-134A WITH KG OF R-134A
MAXIMUM REFRIGERANT WORKING PRESSURE
HI SIDE 15.2 BAR
FACTORY TEST PRESSURE
HI SIDE 16.7 BAR
FIELD LEAK TEST PRESSURE
TESTED AT
LEAK TEST AND CHARGING SPECIFICATION ARE SUPPLIED
IN CONTROL PANEL (SERVICE LITERATURE MANUAL)
MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING
U.S. PATENTS: 4686834 4689967 4715190 5056032
5058031 5434738 5563489 5836382
SERVICE LITERATURE
INSTALLATION, OPERATION AND MAINTENANCE MANUAL:
CVGF-SVN02A-EN AND CVGF-SVU02A-EN
"FOR INSTALLATION REQUIREMENTS, USE ELECTRICAL
CHARACTERISTICS NOT PRODUCT DESCRIPTION"
PRODUCT DESCRIPTION:
MODL CVGF
DSEQ A0
HRTZ 50
CPKW 338
EVBS C
EVTB TE25
EVWP 2
EVCO FLGE
CDBS C
CDTB TE28
CDCO FLGE
CDWA RERE
SPKGEXPS
INSL YES
TRMM TRMS
LCLD CLDC
SRRL 952
PNCO DISC
S.O. NO:
380 VOLTS
50HZ 3PH
338 kW
345- 422 VAC
726 AMPS
1200 AMPS
1200 AMPS
MAX
MAX
VOLTS-AC
HZ PH RLA
380 50
3
380
50
31.43 FLA
115
50
1000 WATTS TOTAL
115
50
1500 VA MAX
ACTUALLY CHARGED
LOW SIDE 15.2 BAR
LOW SIDE 16.7 BAR
BAR
NTON 500
CPIM 940
EFLD WATE
EVWA RERE
CFLD WATE
ORSZ 23
OPTM YES
LANG ENGL
TEST PTR3
LRAY
577
1048
3286
82.50 BAR MAX.
VOLT 380
EVSZ 500
EVWB NM15
CDSZ 500
CDWB NM15
AGLT UL
WVUO YES
SRTY USTR
5