AUX button/ button A on keyfob transmitters MCT-234,
MCT-237 and wireless commanders MCM-140+. Two
options are offered for each AUX button:
Instant: Pressing the AUX button while the exit delay is in
progress will cause the system to arm "instant" (the entry
delay is canceled).
Skip exit delay: Pressing the AUX button will immediately
cause the system to arm immediately.

4.4.18 AUX Button B 2-W-KF

(Fig. 4.4, loc. 18). Applicable only for 2-way keyfob
MCT-237. Same as 4.4.17 but for AUX button B.

4.4.19 Jam Detect

(Fig. 4.4, location 19). Here you determine whether
jamming (interfering transmissions, on the radio channel
used by the system) will be detected and reported or not.
If a jam detection option is selected, the system does not
allow arming under the relevant jamming conditions.
Jam Detection Options
Option
Detection and Reporting when
UL (20/20)
There is continuous 20 seconds of
(USA standard)
jamming
EN (30/60)
There is an accumulated 30 seconds of
(Europe standard)
jamming within 60 sec.
class 6 (30/60)
Like EN (30/60) but the event will be
(British standard)
reported only if the jamming duration
exceeds 5 minutes.
Disabled
(No jamming detection and reporting).

4.4.20 Latchkey

(Fig. 4.4, location 20). Here you determine whether the
system can be armed in the latchkey mode. If the system
is armed this way, a "latchkey" message will be sent to
specific telephones upon disarming by a "latchkey user"
(users 5-8 or keyfob transmitters 5-8). This mode is useful
when parents at work want to be informed of a child's
return from school. The options are: Latchkey ON and
Latchkey OFF.

4.4.21 "Not Active"

(Fig. 4.4, location 21). Here you determine the time limit for
reception of signals from sensors used to monitor the
activity of sick, elderly or disabled people. If no sensor
detects and reports movement at least once within the
defined time limit, a "not-active" alert is initiated.
Options: 3, 6, 12, 24, 48, 72 hours and no act disable.
Note: The Not Active timer is defined for the entire alarm
system for the above hour options and not per partition (in a
PowerMaxExpress Partition system). Subsequently, a
dedicated timer is assigned to each partition.

4.4.22 Back Light (Optional)

(Fig. 4.4, location 22). Here you determine whether the
keypad back lighting will remain on at all times or will turn
on when a key is pressed and turn off within 10 seconds if
no further keystrokes are sensed.
The two options are: always on and off after 10 s.
Note: Back Light can be used only if this option is
available on the purchased control panel.
14

4.4.23 Duress

(Fig. 4.4, loc. 23). A duress alarm (ambush) message can
be sent to the central station if the user is forced to disarm
the system under violence or menace. To initiate a duress
message, the user must disarm the system with the duress
code (2580 by default). Here you can change the code
digits or enter "0000" to disable the duress feature. The
system does not allow the user to program the duress
code saved in this memory location as an existing user
code.

4.4.24 Piezo Siren

(Fig. 4.4, location 24). Here you determine whether the
internal siren will sound or remain silent upon alarm
(according to the user preference). Options: piezo siren
on, piezo siren off.

4.4.25 Reset Option

(Fig. 4.4, location 25). (Not applicable in the USA)
Here you determine whether the system can be rearmed
(after an event) by the user or only by the installer.
Options: user reset or engineer reset.
If Engineer Reset is selected, the system can be rearmed
only by the installer; by entering and exiting the installer
menu, by entering and exiting the event log (see section 7),
or by remote telephone. To perform Engineer Reset via the
telephone,
establish
PowerMaxExpress (see user guide, par. 6.3A, steps 1-5)
and continue as follows:
a.
[*], [installer code], [#]
b. Wait for 2 beeps
c.
[*], [1], [#]
d.
[*], [99], [#]
Note: This menu is not available when partition is enabled.

4.4.26 Tamper Option

(Fig. 4.4, location 26). Here you determine whether zone
tamper will be reported or ignored. Available options are:
zone tamper ON and zone tamper OFF.
Note: To comply with EN requirements, "zone tamper ON"
must be selected.

4.4.27 Siren On Line

(Fig. 4.4, location 27). Here you determine whether the
siren will be activated or not when the telephone line fails
during system armed state. Available options are: enable
on fail, disable on fail.

4.4.28 Memory Prompt

(Fig. 4.4, location 28). Here you determine whether the user
will receive indication that an alarm has been activated.
Available options are: enable and disable.

4.4.29 Disarm Option

(Fig. 4.4, location 29). Here you determine when it is possible
to disarm the system:
A. Any time.
B. In AWAY mode, during entry delay, by using the
PowerMaxExpress keypad or wireless sensor (keyfob).
C. In AWAY mode, during entry delay, by using a wireless
device (keyfob) only (this is set as a default in UK to
comply with DD243).
D. During entry delay, or by using the PowerMaxExpress
keypad in AWAY mode.
Options: any time, on entry all, on entry wireless, or
entry + away kp.
communication