6. Monitor Parameters & EQ Facilities

Monitor Parameters

In order to access the Monitor parameters & EQ facilities page, see Fig. 11; click once on any monitor
on the network in the main page you would like to EQ or select a monitor from the drop down menu
and press the <Edit> button.
Fig.11. Monitor parameters window
The monitor parameters that may be adjusted in this window are:
<Polarity 180 deg>
This function is only available on the subwoofer. Check the box to reverse the polarity
of the subwoofer.
<Lck >
This facility disables the Polarity 180 deg option in case of accidental activation.
If locked the no alteration is possible from the master monitor or iDP SOFT
<LFE>
Mark this box to activate the Low pass filter (120hz). Again this function is only
available on the subwoofer.
<Room Position>
Assuming that no RTA measurement system is being used you can set the position
in the room of each respective monitor using the drop down menu. There is an
<Lck> (Lock) facility to disable the room position facility in case of
accidental activation. If locked then no alteration is possible from the master monitor
or iDP SOFT
TM
.
The monitor room positions available for selection are:
Neutral – freestanding away from boundaries
Wall – against a wall i.e. one boundary
Corner – in a corner i.e. two boundaries
Console – located above console in very close proximity ie on meter bridge
Console Wall – above console against a wall
Console Corner – above console in corner
TM
.
17