2. To Remotely Program the RC-3
Step 1.
Place the TALK BATTERY switch in the OFF position.
Step 2.
Connect the IN screw terminals to a CO line or analog PABX/KSU extension.
Step 3.
Call in to the unit.
Step 4.
When the unit answers, one or two beeps should be heard.
Enter Q plus the security code (factory set to 845464).
Step 5.
Step 6.
Two beeps indicate that you are in programming.
Step 1.
Place the TALK BATTERY switch in the OFF position.
Step 2.
Connect the IN screw terminals to a CO line or analog PABX/KSU extension.
Step 3.
Turn Dipswitch 3 (Learn Mode) ON.
Step 4.
Call in to the unit.
Step 5.
The unit answers after one ring and two beeps indicate that you are in programming.
Step 6.
Be sure to return dip switch 3 to the OFF position when finished.
Note: To leave programming, enter ##7 for immediate RC-3 hangup or just hang up the remote phone and the RC-3 will hang
up 20 seconds later.
C. Programming Acknowledgment Beeps
The RC-3 acknowledges each correct programming entry with two beeps, and indicates incorrect entries by giving three beeps.
Note: During remote programming, a 20-second timer is running in the background. The timer is reloaded whenever a touch tone
is entered, so it is possible to stay in programming as long as at least one touch tone is entered every 20 seconds. If no touch tones
are entered for 20 seconds, the programming timer expires, the RC-3 gives three beeps and hangs up.
D. Quick Programming Features
Acknowledgement Tones
Enable acknowledgement tones (factory setting) ..................................................................................
Disable acknowledgement tones ...........................................................................................................
Programming Relay Commands and Relay Timing
Latch Relay 1 OFF .........................................................................................................................
Latch Relay 1 ON ...........................................................................................................................
Relay 1 timed closure .....................................................................................................................
Interrogate Relay 1 .........................................................................................................................
Relay 1 timed relay activation (HHMMSS), 18 hour maximum (000000 or blank is disabled,
factory set to 5 seconds) ................................................................................................................
Latch Relay 2 OFF .........................................................................................................................
Latch Relay 2 ON ...........................................................................................................................
Relay 2 timed closure .....................................................................................................................
Interrogate Relay 2 .........................................................................................................................
Relay 2 timed relay activation (HHMMSS), 18 hour maximum (000000 or blank is disabled,
factory set to 5 seconds) ................................................................................................................
Latch Relay 3 OFF .........................................................................................................................
Latch Relay 3 ON ...........................................................................................................................
Relay 3 timed closure .....................................................................................................................
Interrogate Relay 3 .........................................................................................................................
Relay 3 timed relay activation (HHMMSS), 18 hour maximum (000000 or blank is disabled,
factory set to 5 seconds) ................................................................................................................
To enter Q as part of a command ...................................................................................................
To enter # as part of a command ....................................................................................................
Disable any of the above relay commands or timing ......................................................................
6
- OR -
Enter Digits
Q
1
Q
2
Enter
Memory
Digits
-then-
Location
1-3 digits
#10
+
1-3 digits
#11
+
1-3 digits
#12
+
1-3 digits
#13
+
6 digits
#14
+
1-3 digits
#20
+
1-3 digits
#21
+
1-3 digits
#22
+
1-3 digits
#23
+
6 digits
#24
+
1-3 digits
#30
+
1-3 digits
#31
+
1-3 digits
#32
+
1-3 digits
#33
+
6 digits
#34
+
QQ
Q#