Download Print this page
Viking RC-3 Technical Practice

Viking RC-3 Technical Practice

3 relay remote touch tone controller
Hide thumbs Also See for RC-3:

Advertisement

Quick Links

TECHNICAL
TECHNICAL
T
T
E
L
E
E
L
E
F
e
a
t
u
r
e
s
F
e
a
t
u
r
e
s
• Operational commands can be customized
1,2 or 3 digits in length
• User Touch Tone programmable
• Non-volatile E
2
memory
• 6 digit security code (to access programming)
• 1-6 digit access code (disable or enable
for additional control security)
• Switchable 32V talk battery
• Relay interrogation tones
• Programmable relay time delays
• Cascade up to three RC-3's to control up to
nine relays
• Programmable ring delay before answering
• Status LED's for relays 1, 2, 3 and power
• One power adaptor can power up to three
units
S
S
C
O
M
O
L
U
T
I
O
N
S
C
O
M
O
L
U
T
I
O
N
S
Control 1 to 9 Relays Remotely
P
r
a
c
P
r
a
c
2
1
C
2
1
C
F
O
R
T
H
E
S
T
F
O
R
T
H
E
S
T
The RC-3 enables a standard Touch Tone
phone to control up to 3 maintained ON, main-
tained OFF, or momentary relay contacts from
a remote location. The RC-3 is fully user pro-
grammable and uses non-volatile E
Up to three RC-3's can be daisy chained on
the same line to control up to nine relays.
The RC-3 features switchable 32V talk battery
allowing easy installation on the trunk port. In
addition, the unit can be connected directly to
a C.O. line or analog PABX/KSU station.
A
p
p
l
i
A
p
p
l
Remote Control of:
• High security building entry systems
• Door strikes and gates in conjunction with
doorboxes (W-1000, etc.)
• Signs, lights, cameras, sprinklers, motors
• Other contact controlled equipment
h
t
t
p
h
t
t
S
p
e
c
S
p
e
c
Power: 12-24V AC or DC, 120V AC/12V DC 500mA UL listed
adapter provided
Shipping Weight: 0.54 kg (1.2 lbs)
Dimensions: 133mm x 89mm x 44mm (5.25" x 3.5" x 1.75")
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95%
non-condensing humidity
Talk Battery Output: 32V DC
Relay contact ratings: 5A @ 30VDC / 250VAC (relay 1), 0.5A
@ 125VAC / 1A @ 30VDC (relays 2 and 3)
Connections: (1) 6 position screw terminal strip, (1) 9 position
screw terminal strip
RC-3
3 Relay Remote Touch
t
i
c
e
t
i
c
e
Tone Controller
April 18, 2012
E
N
T
U
R
Y
E
N
T
U
R
Y
c
a
t
i
o
n
s
i
c
a
t
i
o
n
s
i
n
f
o
@
v
i
k
i
n
g
e
l
i
n
f
o
@
v
i
k
i
n
g
e
l
:
/
/
w
w
w
.
v
i
k
i
n
g
e
l
p
:
/
/
w
w
w
.
v
i
k
i
n
g
e
l
i
f
i
c
a
t
i
o
n
s
i
f
i
c
a
t
i
o
n
s
RC-3
2
memory.
e
c
t
r
o
n
i
c
s
.
c
o
m
e
c
t
r
o
n
i
c
s
.
c
o
m
e
c
t
r
o
n
i
c
s
.
c
o
m
e
c
t
r
o
n
i
c
s
.
c
o
m

Advertisement

loading

Summary of Contents for Viking RC-3

  • Page 1 • Switchable 32V talk battery • Relay interrogation tones • Programmable relay time delays • Cascade up to three RC-3’s to control up to Power: 12-24V AC or DC, 120V AC/12V DC 500mA UL listed nine relays adapter provided Shipping Weight: 0.54 kg (1.2 lbs)
  • Page 2 Access Code is enabled (dip switch 2 ON). The timer has a default value of 20 seconds and counts down in the background when the RC-3 is in the Relay Control State. Every time a touch tone is entered, the Access Timer is reloaded, so it is possible to stay in the Relay Control State as long as touch tones are being entered.
  • Page 3 The Parallel Connection allows the RC-3 to function properly in the cases when it is not possible to wire all devices that share the line through the “In” and “Out” of the RC-3. To use the Parallel Connection, tap off the phone line or talk path and connect it to the “In” side of the RC-3 and set the Talk Battery switch to OFF.
  • Page 4 2. Battery feed switches on both slave units must be in the OFF position for Ring Trip applications. The battery feed switch of slave RC-3 #1 should be set to ON in Trunk applications with only two RC-3’s total and OFF with three RC-3’s. The battery feed switch of slave RC-3 #2 should be set to ON in Trunk applications.
  • Page 5 C. Default Slave Commands As shown in Installation section B, multiple RC-3 units can be stacked to control up to 9 relays in larger applications. The master unit is assigned relay numbers 1-3, while the first slave has 4-6, and the second slave has 7-9. Default relay commands for the slave units then have a first digit of 4-6 or 7-9, and a second digit the same as the master unit (see section A above).
  • Page 6 Step 6. Be sure to return dip switch 3 to the OFF position when finished. Note: To leave programming, enter ##7 for immediate RC-3 hangup or just hang up the remote phone and the RC-3 will hang up 20 seconds later.
  • Page 7 All other operational beeps are still provided by the RC-3. It will still provide one or two beeps when it answers a call (in Ring Trip Connection), two beeps after a valid...
  • Page 8: Series Connection

    ID data). The “ Q ” from the E-30 will set the RC-3 to the Relay Control State. Note 5: Programming a pause as part of a phone number in the E-30 will set the RC-3 to the Relay Control State, since a pause in the E-30 is programmed with “...