Precis HT General Specifications

General Specifications
Approvals
Humidity
Operational Temperature
MTBF
AC Power
Fuse
Power Consumption (max.)
Power Consumption (typical)
Thermal Dissipation (max.)
Thermal Dissipation (typical)
Dimensions
Depth
Width with rack ears
Width without rack ears
Height
Weight
For individual signal information and specifications, see "Signal Types & Specifications" on page 33.
AMX reserves the right to modify its products and their specifications without notice.
Configuration Information & Control Options
The configuration file is stored in the CPU and contains routing and control information for an
AMX AutoPatch Routing System. Each system is pre-engineered (configured) at the factory.
Configuration Information
A copy of the custom configuration file is provided on the AMX AutoPatch CD that ships with each
system. The configuration software, XNConnect, is provided on the CD and can be used to further
customize the configuration file (see "Appendix A – Managing Configuration Files" on page 45).
Unless you need to modify your system, you will not need to use any of the configuration software that
is included on the CD. Always make a copy of the configuration file before modifying it.
Configuration file modifications include basic tasks, such as creating local presets, customizing input
and output channel names for control display (e.g., in APWeb's control interface), as well as advanced
tasks, such as creating a joined virtual matrix. Configuration file modifications are made with
XNConnect, which graphically displays the AMX AutoPatch system and its control configuration.
Precis HT Instruction Manual
Parameter
CE, ETL, cETL
0 to 90% non-condensing
32° F to 110° F (0° C to 43° C)
87,600 hours
100 VAC to 240 VAC single phase, 50 Hz to 60 Hz
1 A, 250 V, 5 mm x 20 mm
80 Watts
57 Watts per fully loaded enclosure
273 BTU/hr.
194 BTU/hr. per fully loaded enclosure
10.4 in. (26.4 cm)
18.8 in. (47.7 cm)
17.4 in. (44.2 cm)
5.2 in. (13.2 cm) 3 RU
Approximately 12 lb. (5.4 kg) per enclosure
Overview & General Specifications
Value
11