10. IF Gain Uncertainty Test
2 dB Gain Steps
2-36 Performance Tests
13. Press
14. Set
[
REFERENCE
15. Press MARKER (OFF). Set CVlDEo] to 100 Hz.
16. Set the frequency synthesizer for an output power level of -3.9
17. Press MARKER
[
PEAK
18. Set the analyzer
amplitude according to 'Iable 2-13. At each setting, note the MKR
A amplitude and record it in the table.
- 1 . 9
- 3 . 9
- 5 . 9
- 7 . 9
- 9 . 9
Figure 2-19. IF Gain Uncertainty Measurement (2 dB)
7.
to -1.9 dBm.
and the frequency synthesizer
)
LEVEL
Deviation
Frequency
)
LEVEL
Synthesizer (MARKER A
Amplitude
'Amplitude
- 3 . 9
- 5 . 9
- 7 . 9
- 9 . 9
-11.9
0 (ref)
2 . 0 0