Follow these steps to enable IEEE 802.3af Power-over-Ethernet support on the four front-
panel BSC-600/1200 Controller Managed ports:
1.
Connect the PoE power supply included in your BSC-600/1200 distribution to a
grounded, 85 to 246 VAC power source.
Connect the PoE power supply's three-pin connector to the mating connector located
2.
on the back of the BSC-600/1200's chassis as shown in Figure 2-9.
3.
Power up the BSC-600/1200 Controller by following the procedure given in
"Connecting the BSC to its Power Source" on page 2-13.
The BSC-600/1200 is now capable of supplying power to 802.3af Power-over-Ethernet-
capable devices, such as the BlueSecure 1500 Access Point, directly connected to its four
front-panel Managed ports.

LED Run Time Mode for BSC-600 and BSC-1200

The system status LEDs are arranged on the left side of the BSC-1200 front panel as
follows:
Power (blue), Activity (green), System(green)
Fault (amber), Media (green), Test(green)
The run time state of the status LEDs shall be as follows:
"Fault" LED shall be set to OFF.
"Activity" LED shall blink when system activity is sensed.
"Media" LED shall blink when onboard storage Flash activity is sensed.
"System" LED shall be set to ON to indicate that system status is good.
"Test" LED shall be set to OFF to indicate that the system is in run time mode.
The "Fault" LED shall also be used for a visual indication that one of the BSC-1200's two
front panel pushbuttons has been pushed and sensed by software. "Fault" shall be set to
blink when either the ON/OFF or RESTART button has been sensed, and shall continue to
blink until the system powers OFF or resets.

Basic POE LED Functionality for BSC-600 and BSC-1200

POE enabled:
OFF - port disabled from GUI
ON steady - port enabled from GUI
(blink is not used)
POE activity
OFF: No POE brick, or port disabled from GUI.
ON blinking: Port enabled, but AP not getting power from BSC (or unplugged).
ON steady: Port getting power from BSC.
BlueSecure™ Controller Setup and Administration Guide
LED Run Time Mode for BSC-600 and BSC-1200

Figure 2-9: Location of BSC-600 PoE Power Supply Connector

Power over Ethernet
Power Supply Connector
2-15