Chapter 2: Installation
LCD
The BSC provides a 2x16 character, liquid crystal display (LCD) to display the IP address
configured for its protected interface.
Power Control
If the BSC is running and you press the front-panel Power button, the BSC will stop all
active services after a slight delay. After all services are shut down, the BSC executes its
normal power-down sequence and shuts off completely.
Reset Control
Press the Reset button to perform a hard reset of the BSC-2100. However, we recommend
that you use the Reset button only if the BSC does not respond after you have tried to
power it down using either the Power button or the BSC's software shutdown function.
Serial Port
The BSC provides a serial port equipped with a DB-9, male connector to support local
console configuration of the BSC. Normally, you will never use the BSC serial port. You
should configure the BSC via its serial interface only in the rare event that you lose access
to the BSC's web interface due to an Internet service outage. The BSC serial interface
supports only a subset of the BSC's configurable parameters. See "Serial Port Access to
Essential Functions" on page D-1 for details about accessing the BSC serial interface.
Fail Over Port
Use the Fail Over port to connect the BSC to another BSC via Ethernet for failover
operation. The Fail Over port is equipped with a copper, RJ-45 10/100 Mbps Ethernet
connector. Use a crossover cable with no switches or hubs in between to connect the two
failover BSCs directly together.
Configuration of the BSC for failover operation is described in "Configuring Failover
Parameters" on page 4-25.
Managed Port
Use the Managed Port to connect the BSC to the managed side (i.e., the wireless side) of
your network via Ethernet. The BSC-2100 Managed Port is equipped with a copper, RJ-
45 10/100/1000 Mbps Ethernet connector (standard) or a 1000BaseSX SC-style
connector (optional).
Protected Port
Use the Protected Port to connect the BSC to the protected side (i.e., the wired side) of
your network via Ethernet. The BSC-2100 Managed Port is equipped with a copper, RJ-
45 10/100/1000 Mbps Ethernet connector (standard) or a 1000BaseSX SC-style
connector (optional).

BSC-1200 Displays, Controls, and Connectors

The following figure shows the Bluesocket BSC-1200 front panel displays, controls, and
connectors.