Status LEDs
The following table summarizes the status indicated by the Bluesocket BSC-1200
BlueSecure Controller light emitting diodes (LEDs).
System
Protected
Managed
Fail Over
POWER
LCD
The BSC provides a 2x16 character liquid crystal display (LCD) to display the IP address
configured for its protected interface.
Shutdown/
If the BSC is running and you press the front-panel Shutdown/Restart button, the BSC will
Restart Control
stop all active services after a slight delay. When all BSC services are shutdown, the
message
To power down the BSC-1200 while the
the rear panel power switch to the OFF(O) position.
To restart the BSC-1200 while the
front-panel Shutdown/Restart button a second time.The BSC services will restart again
after a slight delay. In approximately 30 to 60 seconds, the LCD display indicates that
BSC services have re-started.
Serial Port
The BSC provides a serial port equipped with a DB-9, male connector to support local
console configuration of the BSC. Normally, you will never use the BSC serial port. You
should configure the BSC via its serial interface only in the rare event that you lose access
to the BSC's web interface due to an Internet service outage. The BSC serial interface
supports only a subset of the BSC's configurable parameters. See "Serial Port Access to
Essential Functions" on page D-1 for details about accessing the BSC serial interface.
Fail Over Port
Use the Fail Over port to connect the BSC to another BSC via Ethernet for failover
operation. The Fail Over port is equipped with a copper, RJ-45 10/100 Mbps Ethernet
connector. Use a straight through cable with no switches or hubs in between to connect
the two failover BSCs directly together.
Configuration of the BSC for failover operation is described in "Configuring Failover
Parameters" on page 4-25.
BlueSecure™ Controller Setup and Administration Guide

Figure 2-3: BSC-1200 Displays, Controls, and Connectors

Table 2-1: BSC-1200 Status LEDs

LED
100/Status
Lights to indicate the BSC system is running and
its CPU is active.
Lights to indicate that the BSC Protected Port is
connected to a Fast Ethernet (100 Mbps)
network.
Lights to indicate that the BSC Managed Port is
connected to a Fast Ethernet (100 Mbps)
network.
Lights to indicate that the BSC Fail Over Port is
connected to another BSC via Fast Ethernet
(100 Mbps).
Lights when the BSC is connected to an AC power source and its rear-panel power switch is in the
ON position (|).
Bluesocket Stopped
BSC-1200 Displays, Controls, and Connectors
Flickers when the BSC is writing data to or
reading data from non-volatile memory.
Lights when a valid link has been established on
the Ethernet cable connected to the Protected
Port. Flickers when data is received on the
Protected Port.
Lights when a valid link has been established on
the Ethernet cable connected to the Managed
Port. Flickers when data is received on the
Managed Port.
Lights when a valid link has been established on
the Ethernet cable connected to the Fail Over
Port. Flickers when data is received on the Fail
Over Port.
On/Off
appears on the LCD display.
Bluesocket Stopped
Bluesocket Stopped
Link/Activity
message is displayed, set
message is displayed, press the
2-7