Section 3 Engineering Guidelines
Hardware
VT100 Terminal Interface
Data Rate
Data Bits
Parity
Stop Bits
Terminal Emulation
Mechanical and Environmental (IDU)
Operating Temperature
Size
Humidity
Weight
Mechanical and Environmental (ODU)
Operating Temperature
Size
Humidity
Weight
Power
Input Voltage
Power Consumption
Connector
Fuse
Network Modules
Quad E1 Module
Connection
(120Ω Interface)
Capacity
Line Code
Alarms
Loopbacks
42
Table 16. At-A-Glance Specifications (Continued)
Description
Copyright © 2005 ADTRAN, Inc.
TRACER 6000 Series Split System Manual
Specification
9600, 19200, 38400, 57600, 115200 bps
8
None
1
VT100
-25°C to 65°C
1.7 inch (4.4 cm) H
17.2 inch (43.7 cm) W
11.4 inch (28.9 cm) D
95 percent, noncondensing
5 lbs (2.3 kg)
-40°C to 65°C
12.74 inch (32.36 cm) H
10.24 inch (26.01 cm) W
4.78 inch (12.14 cm) D
95 percent, noncondensing
9.5 lbs (4.3 kg)
21 to 60 VDC, either polarity referenced to ground
< 25 W
2-pin terminal block (DC)
2 A, 250 V slow-blo fuse (2-inch)
Four RJ-45 interfaces
4xE1 (CCITT G.703)
HDB3 (default), AMI
LOS, LCV, AIS, RMT, OOF, CRC
Local and remote line and link
612806320L1-1B