ADTRAN AHT1U Installation & Maintenance

Low voltage asynchronous htu-c line card for dsc communications corporation litespan channel bank assemblies
Hide thumbs Also See for AHT1U:

Advertisement

Quick Links

LOW VOLTAGE ASYNCHRONOUS HTU-C LINE CARD
1.
GENERAL ............................................................................ 1
2.
APPLICATIONS .................................................................. 3
3.
INSTALLATION .................................................................. 4
4.
CONTROL PORT OPERATION ......................................... 6
5.
ALARMS ............................................................................ 13
6.
HDSL DEPLOYMENT GUIDELINES ............................. 16
7.
TROUBLESHOOTING PROCEDURES .......................... 17
8.
MAINTENANCE ............................................................... 17
9.
PRODUCT SPECIFICATIONS ......................................... 17
10. WARRANTY AND CUSTOMER SERVICE ................... 18
Appendix A. HDSL LOOPBACKS ......................................... A-1
FIGURES
ADTRAN AHT1U .................................................. 1
HTU-C Span Powering Diagram ........................... 3
Assembly ................................................................ 3
HTU-C Card Edge Connections ............................. 4
RS232 (DB9) Connector ........................................ 6
HDSL Main Menu Screen ...................................... 9
Provisioning Screen .............................................. 12
Troubleshooting, Dual Loop Screen .................... 13
HDSL Deployment Guidelines ............................ 15
Figure A-1. HDSL Loopback Points ...................................... A-1
Figure A-2. Element State Diagram ....................................... A-1
TABLES
Screen Abbreviations ................................................. 6
Provisioning Options ............................................... 14
LED Alarms ............................................................. 15
TL1 Alarm Conditions ............................................. 15
HDSL Loss Values .................................................. 16
Loop Insertion Loss Data ........................................ 17
Worksheet PW-1 Replacements .............................. 17
Worksheet PW-1 ...................................................... 17
Troubleshooting Guide ............................................ 18
ADTRAN AHT1U Specifications ........................... 19
Table A-1. HDSL Loopback Control Codes ........................... A-2
61245002L6-5C
ADTRAN AHT1U
FOR DSC COMMUNICATIONS CORPORATION
®
CHANNEL BANK ASSEMBLIES
INSTALLATION/MAINTENANCE
Section 61245002L6-5, Issue 2
Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.

Figure 1. ADTRAN AHT1U

1. GENERAL
The ADTRAN Low Voltage asynchronous Litespan
HDSL Transceiver Unit for the Central Office
(HTU-C) list 6, is a DS1 interface unit that provides
full T1 service over 4-wire interface facilities. The
Low Voltage Litespan HTU-Cs combine ADTRAN
HDSL technology and DSC Litespan technology to
provide an HDSL interface to a Litespan system.
ADTRAN's Low Voltage Litespan HTU-C is
certified by DSC to safely operate in Litespan 2000
and Starspan systems. The unit is licensed under the
Asynchronous High-bit-rate Digital Subscriber Line
TI Interface Unit (AHT1U) channel unit type.
Figure 1 is an illustration of the ADTRAN AHT1U.
Section 61245002L6-5C
Issue 3, February 2001
CLEI Code # SLL110XHAA
H T U -C
2L 6
12 45 00
LO O P
FA IL
HD SL
2
LP 1 LP
R
S
2
3
2
A H T 1U
1

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN AHT1U

  • Page 1: Table Of Contents

    TL1 Alarm Conditions ..........15 TI Interface Unit (AHT1U) channel unit type. Table E. HDSL Loss Values ..........16 Figure 1 is an illustration of the ADTRAN AHT1U. Table F. Loop Insertion Loss Data ........17 Table G. Worksheet PW-1 Replacements ......17 Table H.
  • Page 2 • 1244042L1, Low Voltage 819A HRE Asynchronous counterparts to the Litespan HTU-C • 1244044L1, Low Voltage 439 HRE (AHT1U) are the asynchronous DSX-1 interface unit The HTU-C can be deployed in circuits consisting of one (ADS1U) and the asynchronous T1 interface unit HTU-C and one HTU-R.
  • Page 3: Litespan

    2. APPLICATIONS ADTRAN uses negative ground-referenced span powering voltage (-135 VDC) on HDSL loop 2 while The ADTRAN HDSL system provides a cost-effective loop 1 remains at ground. This prevents corrosion alternative for deploying T1 service over metallic associated with positive ground reference voltage cable pairs.
  • Page 4: Installation

    Litespan bank recognizes the insertion of the linecard. Reinsertion any earlier than this card and downloads the AHT1U channel unit type may temporarily lock the HTU-C into a code into the linecard. Typically, the FAIL LED will...
  • Page 5 Provisioning The Litespan HTU-C is provisioned in two steps. First, local HTU-C provisioning is set using the RS-232 port. Typical T1 provisioning options are set for the Litespan HTU-C. Second, Litespan system provisioning through a Litespan craft interface port allows a data cross-connection between the Litespan HTU-C and another linecard in the asynchronous T1 linecard class or another Litespan HTU-C.
  • Page 6: Control Port Operation

    The terminal interface operates at data rates from 4. CONTROL PORT OPERATION 1.2 kbps to 19.2 kbps. The asynchronous data format The Litespan HTU-C provides a faceplate-mounted is fixed at 8 data bits, no parity and 1 stop bit. The female DB9 connector that supplies an RS232 supported terminal type is VT-100 or compatible.
  • Page 7 The screens illustrated in Figures 6 through 14 are for Figure 8 consolidates current information for the an HDSL circuit deployed with ADTRAN HDSL HDSL, DSX-1, and DS1 interfaces. A key to the technology. The circuit includes an HTU-C, HTU-R information provided is found in the center of the and HRE for inclusiveness of functionality.
  • Page 8 DSX-1 in the HDSL screens actually refers to a virtual Performance Monitoring DS1 channel provided by the time slot interchanger The Performance History screen is shown in Figures 9 unit (TSI) of the Litespan CBA to the Litespan and 10. Type “H” to view the Performance History linecard (see DSC Litespan documentation for more screen for the HRE.
  • Page 9: Figure 6. Hdsl Main Menu Screen

    CIRCUIT ID: EMUL 10/06/98 00:25:00 ADTRAN HDSL MAIN MENU 1) CURRENT SYSTEM STATUS 2) PERFORMANCE HISTORY 3) ADTRAN INFORMATION 4) LOOPBACK OPTIONS 5) PROVISIONING 6) TROUBLESHOOTING 7) SET TIME/DATE/CIRCUIT ID Choose a screen by pressing the corresponding number. Figure 6. HDSL Main Menu Screen...
  • Page 10: Figure 8. Current System Status, Dual Loop Screen

    LOOP #1 <NETWORK> LOOP #2 CURRENT SYSTEM STATUS LOOP #1 <CUSTOMER>LOOP #2 --------- HTU-C --------- --------- HTU-R --------- 31(31) dB 30(30) dB <- LOSS CUR(MAX) -> 31(31) dB 31(31) dB <- SYNC -> 000/00000 000/00000 <- 15M/24H -> 000/00000 000/00000 000/00000 000/00000 <-...
  • Page 11: Figure 10. Performance History, Dual Loop Screen

    Phone: 800.726.8663 / 888.873.HDSL Fax: 256.963.6217 Internet: www.adtran.com ------------------------------------------------------------------------------- HTU-C INFORMATION HTU-R INFORMATION ----------------- ------------------ S/N : S/N : CLEI: CLEI: MANF: MANF: Press “M” to view Main Menu. Figure 11. ADTRAN Information, Dual Loop Screen 61245002L6-5C Section 61245002L6-5, Issue 3...
  • Page 12: Figure 12. Loopback Options, Dual Loop Screen

    CIRCUIT ID: XXX 10/06/98 09:23:42 LOOPBACK OPTIONS _____ _____ _____ |HTU-C| |HRE 1| |HTU-R| --->|-----|<============>|-----|<============>|-----|<--- NET | | CUST <---|-----|<============>|-----|<============>|-----|---> |_____| |_____| |_____| 1) LOOPBACK TO NETWORK AT HTU-C = INACTIVE 2) LOOPBACK TO CUSTOMER AT HTU-C = INACTIVE 3) LOOPBACK TO NETWORK AT HTU-R = INACTIVE 4) LOOPBACK TO CUSTOMER AT HTU-R = INACTIVE 5) LOOPBACK TO NETWORK...
  • Page 13: Alarms

    CIRCUIT ID: XXX 10/06/98 09:22:41 TROUBLESHOOTING DISPLAY _____ _____ _____ |HTU-C| |HRE 1| |HTU-R| --->| |<=========>| |<=========>| |<--- NET | | CUST <---| |<=========>| |<=========>| |---> |_____| |_____| |_____| NO ALARM CONDITIONS Press “M” to return to the Main Menu Figure 14.
  • Page 14: Table B. Provisioning Options

    When optioned for T1 mode, the unit does not respond to DDS Latching Loopback codes ....DDS Latching Loopback operation is supported. The AHT1U and any HRE units which are in the HDSL circuit are treated as Identical Tandem Dataports and the HTU-R is treated as a different Tandem Dataport.
  • Page 15: Table C. Led Alarms

    Table C. LED Alarms Indicator Description LOOP ....Illuminates when a loopback to the network is in progress. FAIL ...... Illuminates upon HTU-C powerup. Remains On until the HTU-C is successfully initialized. The length of time to complete this procedure is dependent on activity of the terminal control processor in the common control assembly of the Litespan system.
  • Page 16: Hdsl Deployment Guidelines

    6. HDSL DEPLOYMENT GUIDELINES Loop loss per kft for other wire is summarized in Table E. The ADTRAN HDSL system is designed to provide DS1-based services over loops designed to comply with carrier service area (CSA) guidelines. CSA Table E. HDSL Loss Values deployment guidelines are given below.
  • Page 17: Troubleshooting Procedures

    Table G. Worksheet PW-1 Replacements Configuration A Column Factor B Column Factor C Column Factor Original Worksheet PW-1 values for AHT1U with no repeater 0.430 0.076 0.200 and a span-powered HTU-R. Do not use original worksheet values with ADTRAN products.
  • Page 18: Warranty And Customer Service

    1. Verify that the channel bank or ONU BPS FAIL LEDs are off. 2. Verify that the equipment type for the Litespan HTU-C slot is AHT1U. Using TL1, equipment type is shown with the command rtrv-eqpt::AID, where AID is the access identifier (i.e., cot-1-15).
  • Page 19: Table J. Adtran Aht1U Specifications

    Terminal Type ......... VT 100, or compatible Async Speed ..........1.2 kbps to 19.2 kbps Data Format ..........8 data bits, no parity, 1 stop bit Part Numbers 1245002L6 ..........Asynchronous HTU-C Linecard Unit (AHT1U), Narrowband and Wideband 61245002L6-5C Section 61245002L6-5, Issue 3...
  • Page 20: Appendix Ahdsl Loopbacks

    Appendix A HDSL LOOPBACKS The unit can detect the loopback activation or deactivation HDSL MAINTENANCE MODES code sequence only if an error rate of 1E or better is This appendix describes operation of the HDSL system present. with regard to detection of in-band and ESF facility data link loopback codes.
  • Page 21 Table A-2. Inband Addressable Loopback Codes Function and Code Response Arm ............. NIU Loopback Enabled: The HTU-R will loopup towards the network. No AIS or errors 11000 (also known as a 2-in-5 pattern) will be sent as a result of this loopback. The HTU-C and HRE will arm. Disarm ............

Table of Contents