Section 3 Engineering Guidelines

To ODU Interface (N-Type Connector)

The
interface (N-type connector) is the IDU-side IF connection between the IDU and ODU. The
TO ODU
IDU transmits payload data to the ODU on a 280 MHz carrier and receives the ODU data on a 140 MHz
carrier. The IF connection also provides a full-duplex control and monitoring channel between the IDU and
ODU on a 4.5 MHz carrier. Additionally, this interface provides DC power to the ODU, taken directly
from the voltage supplied to the power connection on the rear of the IDU. The power supply is protected
from a short-circuit on the IDU/ODU connection via a thermal protection device.
5.

TRACER 6320 OUTDOOR UNIT (ODU)

Figure 3 identifies the features of the TRACER 6320 ODU bottom panel and Table 10 provides a brief
description of each interface.
A
Antenna
Connector
Name
A
Antenna
B
GND
C
RSSI
D
Cover
E
To IDU
36
B
C
GND
RSSI
Figure 3. TRACER 6320 ODU Bottom Panel
Table 10. ODU Bottom Panel Description
Connector
Description
N-type (female)
Antenna feedline cable connection
Bantam
Ground reference for the RSSI interface
Bantam
DC voltage indicating strength of the received signal at the
antenna
N/A
Weather-proof (removable) cover for protecting GND and
RSSI interfaces
N-type
Feedline cable for connecting to the Indoor Unit
Copyright © 2005 ADTRAN, Inc.
TRACER 6000 Series Split System Manual
D
Weather-proof
Cover for RSSI and GND
E
Connection
to IDU
612806320L1-1B