What to do if the ADMIN password has been forgotten
If the ADMIN password becomes mislaid or forgotten, you will not be able to
access the AdderView CATxIP 5000 to add or edit users and computer names,
unless you have given other users admin privileges. This situation may be
resolved by performing a complete reset to return the AdderView CATxIP 5000
to factory settings.
IMPORTANT: A complete reset erases all the user names and computer
names that you have setup.
To clear a password (and restore factory
default settings)
1 Remove power from the AdderView
CATxIP 5000 unit.
2 Press and hold the reset button on
the front panel (requires paper clip or
similar).
3 Apply power and after a couple of
seconds release the reset button. The
Maintenance menu will be displayed
4 Highlight 'Reset Configuration' and
press
. The Reset Config warning will
be displayed
5 Highlight 'Reset' and press
settings will be returned to their factory
defaults and the previous Maintenance
menu will be re-displayed.
6 Remove power from the unit and then
re-apply it.
7 You now need to go through the
configuration procedure
and re-
instate all of the required settings.
CATxIP 5000 Maintenance
To upgrade unit, visit:
http://192.168.0.6
Configure Network
Reset Configuration
Return to normal operation
CATxIP 5000 Reset Config
WARNING: Continuing will cause
your existing configuration to
. All
be erased.
When the unit is returned to
normal mode it will require
re-configuring before it can
be used.
DO YOU WISH TO CONTINUE?
initial
RESET
Cancel