OWNER'S MANUAL
MODEL TTP-300 3X3 Commercial Trash Pump
P.O.Box 791, Travelers Rest, S.C. 29690
Phone 864-834-7212
Service/Replacement Parts 800-845-4141
WWW.TITANINDUSTRIAL.NET
WARNING!
Do Not Operate Equipment until reading & understanding Owner's Manual!
The Emission Control System for this pump is warranted for standards set by the Environment Protection Agency.
TTP300 Titan Motor Manual
Revision # 030321A

Advertisement

Table of Contents
loading

Summary of Contents for Titan TTP-300

  • Page 1 ® OWNER’S MANUAL MODEL TTP-300 3X3 Commercial Trash Pump P.O.Box 791, Travelers Rest, S.C. 29690 Phone 864-834-7212 Service/Replacement Parts 800-845-4141 WWW.TITANINDUSTRIAL.NET WARNING! Do Not Operate Equipment until reading & understanding Owner’s Manual! The Emission Control System for this pump is warranted for standards set by the Environment Protection Agency.
  • Page 2 It is extremely important to read and understand the entire contents of this Owner’s Manual for the Titan Industrial- Model TTP300 before attempting to operate the Trash Pump. This is a gas engine powered, industrial strength trash pump. The gas engine and the pump are both potentially hazardous and could cause physical injury or even death if improperly used.
  • Page 3  SAFETY This pump was designed for specific applications. DO NOT attempt to modify the unit in any way or use it for any application that it was not designed to do. Ask the dealer or contact the factory if you have any questions concerning the pump’s application.
  • Page 4 SETTING UP TRASH PUMP MOUNTING  Place the pump as close as possible to the liquid WARNING! being pumped. A level mounting position is Never operate an internal combustion engine in an required for proper operation. explosive atmosphere. Do not operate engine in enclosed areas without proper ventalation To ensure sufficient fuel and lubrication, DO ...
  • Page 5: Starting The Engine

    OPERATION OF THE TRASH PUMP Starting the Engine WARNING! This pump is designed to pump non-volitile, non- (See page 6) flammable liquids containing specified entrained solids. Do not attempt to pump volitile, flam- Always check oil before starting use. mable, or corrosive liquids. CAUTION! Never operate pump unless there is liquid in the pump casing.
  • Page 8 Check the engine oil level with the engine stopped and in a level position. 1. Remove the filler cap/dipstick and wipe it clean. 2. Insert and remove the dipstick without screwing it into the filler neck. Check the oil level shown on the dipstick.
  • Page 10: Troubleshooting

    TROUBLESHOOTING Problem Cause Solution Pump Fails To Prime. 1.Not Enough liquid in casing. 1. Add liquid to casing. 2.Suction valve contaminated or 2. Clean or replace. damaged. 3. Correct leak 3. Air leak in suction line. 4. Replace Suction hose. 4.
  • Page 11 13 11...
  • Page 14 Low Octane Gas Fuel Capacity 2.3 Gallons Ignition System Pull Start Dimensions (inches) L-36" W-21 1/2" H-25" Net Weight 84 LBS Warranty 1 Year Gallons per hour 15840gph TITAN INDUSTRIAL P.O. BOX 791 TRAVELERS REST, SC 29690 PHONE 864-834-7212 WWW.TITANINDUSTRIAL.NET...