Titan DURO PROFESSIONAL Series Operating & Installation Instructions Manual
Titan DURO PROFESSIONAL Series Operating & Installation Instructions Manual

Titan DURO PROFESSIONAL Series Operating & Installation Instructions Manual

Submersible sump pumps

Advertisement

Submersible Sump Pumps
Models:
SBA025T1/SBA025V1 (1/4 hp)
SBA033T1/SBA033V1 (1/3 hp)
SBA050T1/SBA050V1 (1/2 hp)
Operating & Installation Instructions
Save these instructions & keep track of your product's serial#
This manual contains important
safety and operating instructions.
Read all instructions and follow
them when using this product.
Failure to consider this information
and follow these instructions,
including those concerning
maintenance, may result in property
damage, injury and or death.
Canature WaterGroup Canada Inc. ("Canature")
did not design or manufacture this product. Canature
has no knowledge of and makes no representations or
warranties respecting the product's design,
manufacturing, testing, packaging, or inspecting.
Canature has disclosed all known risks associated with
the product within this manual but cannot disclose
risks that are beyond its knowledge.
NOTICE: THIS MANUAL CONTAINS A LIMITED
WARRANTY. BY INSTALLING AND OR USING THIS
PRODUCT, YOU WAIVE CERTAIN LEGAL RIGHTS
INCLUDING THE RIGHT TO SUE OR CLAIM
COMPENSATION IN THE EVENT OF PROPERTY
DAMAGE, INJURY, AND OR DEATH.
PROFESSIONAL SERIES

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DURO PROFESSIONAL Series and is the answer not in the manual?

Questions and answers

Chris Spencer
March 22, 2025

How do you adjust the travel on the vertical float of a ⅓ hp Titan Submersible pump?

1 comments:
Mr. Anderson
May 14, 2025

The travel on the vertical float of a ⅓ hp Titan PROFESSIONAL Series submersible pump cannot be adjusted. The document only provides tether length adjustments for tethered floats, not vertical floats.

This answer is automatically generated

Summary of Contents for Titan DURO PROFESSIONAL Series

  • Page 1 PROFESSIONAL SERIES Submersible Sump Pumps Models: SBA025T1/SBA025V1 (1/4 hp) SBA033T1/SBA033V1 (1/3 hp) SBA050T1/SBA050V1 (1/2 hp) Operating & Installation Instructions Save these instructions & keep track of your product’s serial# Canature WaterGroup Canada Inc. (“Canature”) This manual contains important safety and operating instructions. did not design or manufacture this product.
  • Page 2: Table Of Contents

    Table of Contents Reading this Manual Introduction Safety Guidelines Safety Information Safety Instructions Installation Instructions Read Before Installing or Operating Pump Sump Hole Pump Float Assembly Installation for Proper Pump Operation Pump and Piping Pump Operations Electrical Information Automatic Thermal Overload Protection Maintenance Instructions Cleaning the Pump Troubleshooting Checklist...
  • Page 3: Reading This Manual

    READING THIS MANUAL Save these instructions & keep track of your product’s serial# This manual contains important safety and operating information and instructions based on information known by Canature. Canature has no knowledge of and makes no representations or warranties respecting the product’s design, manufacturing, testing, packaging and inspecting.
  • Page 4: Introduction

    INTRODUCTION The manufacturer is responsible for the design, manufacturing, testing, packaging and inspecting of this pump. Canature does not guarantee the manufacturer’s design, manufacturing, testing, packaging and inspecting. All pumps must be checked for damage prior to installation. Should any damage be identified, notify your dealer. This pump may be used to pump reasonably clean water only.
  • Page 5 SAFETY INFORMATION (CONTINUED) The installation of this pump MUST be in accordance with the Canadian Electrical Code WARNING (CE Code), the National Plumbing Code of Canada (NPC), the International Plumbing Code (IPC), as well as all applicable local codes and ordinances. Do NOT install this pump in any location classified as hazardous by the Canadian WARNING Electrical Code (CE code).
  • Page 6 SAFETY INFORMATION (CONTINUED) Do NOT under any circumstances remove the ground pin. The 3-prong plug MUST be inserted into a mating 3-prong grounded receptacle. WARNING RISK OF ELECTRIC If the installation does not have such a receptacle, it MUST be changed SHOCK to the proper type, wired and grounded in accordance with the Canadian Electrical code and all local codes and ordinances.
  • Page 7: Safety Instructions

    SAFETY INSTRUCTIONS The following safety rules should be followed to avoid serious injury or property damage. NOTE Always remove the plug from the electrical outlet before servicing this pump. 1. Check with your local electrical and plumbing codes to ensure you comply with the regulations. These codes were designed with your safety in mind –...
  • Page 8: Installation Instructions

    INSTALLATION INSTRUCTIONS Read Before Installing or Operating Pump; — This information is provided for your SAFETY and to PREVENT EQUIPMENT PROBLEMS based on the information known to Canature. — Always wear appropriate safety gear, such as safety glasses, when working on the pump or piping. —...
  • Page 9: Pump Float Assembly

    INSTALLATION INSTRUCTIONS (CONTINUED) Pump Float Assembly Model SBA025T1, SBA033T1, and SBA050T1 are supplied with tether float assemblies which are attached to the pump. Models SBA025V1, SBA033V1, and SBA050V1 are supplied with vertical float assemblies. These vertical float assemblies must be attached to the pump. Refer to the following diagram for assembly. Installation for Proper Pump Operation The pump MUST be secured in a manner that prevents the pump from moving.
  • Page 10: Pump Operations

    PUMP OPERATIONS The pump will start when the water has filled the sump to a depth that engages the automatic float switch. The pump will stop when the water depth disengages the automatic float switch. The pump will recycle thereafter as required. Allow pump to go through several cycles to assure satisfactory operation.
  • Page 11: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS This product has been designed as a dewatering pump for flood protection in a residential home. The application of this product is for permanent installation. Conduct annual maintenance of the product, along with periodic checks to be sure the pump is in operational condition. Failure to do so may result in property loss or damage, personal injury and/or death.
  • Page 12: Cleaning The Pump

    CLEANING THE PUMP 1. Always disconnect unit from power supply before any servicing is performed. 2. Disconnect discharge piping and remove pump from sump basin. 3. Submerse pump in a disinfectant solution (Clorox or chlorine) for at least one hour before disassembling pump. DO NOT remove countersunk screws holding seal plate to stator housing or warranty will be void.
  • Page 13: Troubleshooting Checklist

    TROUBLESHOOTING CHECKLIST The following steps are for service and cleaning of the pump; 1. Pump does NOT run or hums a. Tripped breaker, blown or loose fuse or other interruption of power. b. Water level too low for float switch to operate c.
  • Page 14: Warranty

    WARRANTY This product is guaranteed for a period of two (2) years from the date of original retail purchase against defects in materials and workmanship. Subject to the conditions and limitations described below, this product, if returned to us with proof of purchase within the stated warranty period and if covered under this warranty, will be repaired or replaced (with the same model, or one of equal value or specification) –...
  • Page 15: Additional Limitations

    Additional Limitations This warranty applies only to the original purchaser and may NOT be transferred. Neither the retailer nor the manufacturer shall be liable for any other expense, loss of damage, including; without limitation, any indirect, incidental, consequential or exemplary damages arising in connection with the sale, use, or inability to use this product. This warranty shall NOT apply when damage is caused by;...
  • Page 16 Toll Free: 1-877-288-9888 www.canaturewg.com 51448 2022-01-12...

This manual is also suitable for:

Sba025t1Sba025v1Sba033t1Sba033v1Sba050t1Sba050v1

Table of Contents

Save PDF