F Maintenance; G Protection - Zibro S185 Operating Manual

Pvg international b.v.
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
F
MAINTENANCE
Cleaning the front panel
1
Switch the machine off and remove the plug from the socket.
2
Hold the front panel at position "a" and pull it towards you.
3
Clean with a soft dry cloth.
Use lukewarm water (max. 30˚ C) to remove stubborn dirt.
4
Never use volatile substances, such as benzene, or abrasives to
remove dirt.
5
Never spray water on the indoor unit.
Dangerous! Electric shock!
6
Replace the front panel and close it by pushing position "b" down.
Cleaning the air filter
The air filter must be cleaned regularly.
Follow this procedure:
1.
Switch the machine off completely.
-
Open the front panel.
-
Carefully pull the filter handle towards you.
-
Grip the handle and slide the filter out.
2.
Clean and replace the air filter.
To remove stubborn dirt, clean the filter in lukewarm water with detergent. After cleaning, allow the
filter to dry completely out of direct sunlight.
3.
Close the front panel.
If the air conditioner is operating in an extremely dusty environment, it must be cleaned every two
weeks.
G
SAFETY
Operating status
The safety components can detect faults and deactivate the unit in the following cases:
HEATING
The outside temperature is above 24°C
The outside temperature is under -7°C
The room temperature is above 27°C
COOLING
The outside temperature is above 43°C
The room temperature is under 21°C
DRY
The room temperature is under 18°C
4
18