3Ware 720-0186-00 Manual page 41

Sas/sata raid controller
Table of Contents

Advertisement

www.3ware.com
Note:
If an asterisk (*) appears next to the status of a unit, there is an error on one
of the drives in the unit. This feature provides a diagnostic capability for potential
problem drives. The error may not be a repeated error, and may be caused by an
ECC error, SMART failure, or a device error. Rescanning the controller will clear the
drive error status if the condition no longer exists
For controller models up to the 9650SE series, the Port summary section lists
all present ports and specifies the port number, disk status, unit affiliation, size
(in gigabytes) and blocks (512 bytes), and the serial number assigned by the
disk vendor.
For the 9690SA controller series, this section lists virtual ports, and specifies
the VPort number, disk status, unit affilication, drive type, phy number ( if
direct attached), the enclosure and slot (if expander attached), and model
number of the drive.
The BBU summary lists details about the BBU, if one is installed. It includes
a few important attributes such as hours left (in which the current BBU can
backup the controller cache in the event of power loss), temperature, voltage,
readiness, and so forth.
Additional attributes about controllers, units, ports and disks can be obtained
by querying for them explicitly. For details, see the other show subcommands.
Example output for 9650SE and earlier controllers:
//localhost> /c2 show
Unit
UnitType
Status
---------------------------------------------------------------------------
u0
RAID-5
OK
u1
RAID-0
OK
u2
SPARE
OK
u3
RAID-1
OK
Port
Status
---------------------------------------------------------------
p0
OK
p1
OK
p2
OK
p3
OK
p4
OK
p5
OK
p6
OK
p7
OK
p8
OK
p9
NOT-PRESENT
p10
OK
p11
OK
Name
OnlineState
BBUReady
-------------------------------------------------------------------------
bbu
On
Yes
The above output is for 9650SE and earlier controllers.
Controller Object Commands
.
%RCmpl
%V/I/M
Stripe
-
-
64K
-
-
64K
-
-
-
-
-
-
Unit
Size
Blocks
u0
149.05 GB
312581808
u0
149.05 GB
312581808
u0
149.05 GB
312581808
u0
149.05 GB
312581808
u2
149.05 GB
312581808
u3
149.05 GB
312581808
u0
149.05 GB
312581808
u3
149.05 GB
312581808
-
149.05 GB
312581808
-
-
-
u1
149.05 GB
312581808
u1
149.05 GB
312581808
Status
Volt
Temp
OK
OK
OK
Size(GB)
Cache
AVrfy
596.004
ON
OFF
298.002
ON
OFF
149.042
-
OFF
149.001
ON
OFF
Serial
WD-WCANM1771318
WD-WCANM1757592
WD-WCANM1782201
WD-WCANM1753998
WD-WCANM1766952
WD-WCANM1882472
WD-WCANM1883862
WD-WCANM1778008
WD-WCANM1770998
-
WD-WCANM1869003
WD-WCANM1762464
Hours
LastCapTest
241
22-Jun-2004
34

Advertisement

Table of Contents
loading

This manual is also suitable for:

9690sa9590se9550sx9550sxu9500s3ware 9650se

Table of Contents