Canonical Dialing
4.1.2

Canonical Dial Lookup

The following example shows settings suitable for recognizing incoming numbers and assign-
ing them to entries in the local phone book, and for generating correct dial strings from phone
book entries, depending on whether the number is internal or external.
Parameter
Local code <1>
International code <1>
Local code <2>
International code <2>
4-2
Example value Explanation
780
Enterprise node prefix (here: Nottingham).
+44115943
Equivalent prefix to access numbers on this
node from the PSTN. Here, the prefix used by
the PSTN (DID/DDI: direct inward dialing) is
943, which differs from the enterprise node
prefix used within the enterprise network.
722
Enterprise node prefix (here: Munich).
+4989722
Equivalent prefix to access numbers on this
node from the PSTN. Here, the prefix used by
the PSTN for direct inward dialing is identical
to the enterprise node prefix.