11. Insert the pin on the left side of the feed module with the rod (1); align the
upper tab with the slot (2); align the pin on the right side of the feed module
with the rod (3) and turn the green feed module release knob so that it
points to the Locked icon on the left (4) to re-engage the feed module.
Verify that the feed module is securely in place and moves freely after you
install it.
12. Close the scanner cover and the printer access cover.
13. Reinstall the output tray.
14. When finished, access the Maintenance meters on the Operator Control
Panel and touch the Reset icon to reset the Feed Tires/Feed Module
meter.