Wiring Diagram - Regency LIBERTY L900E-NG Owners & Installation Manual

Liberty l900e series gas fireplace
Table of Contents

Advertisement

INSTALLATION
Lockout Led
Black
Reset Button
120V Power Source
NEUTRAL (white)
LIVE (black)
Battery
A receptacle is provided on the left hand side of the unit. 120 Volt AC power
must be wired to the receptacle and the control module plugged in for the
unit to operate fully. The front and rear burners will operate on low, when
the unit is running on battery back-up.
(Do not cut the ground terminal off under any circumstances.)
32

WIRING DIAGRAM

Black
Orange
Green
ECS MODULE
yellow
green
white white
black orange
A
C
D
B
red
black
Flame Sensor
1
J7
2
NG/LP
jumper
Spark Ignitor
B
E
red
black
MODULATING
COIL
(EMBER)
SECONDARY
BURNER
Pin
P.OUT
4
3
2
1
VENT
EV1
EV2
R.Q.
ADJ.
9V SOLENOID
Caution: Ensure that the wires do not touch any hot
surfaces and are away from sharp edges.
CAUTION: Label all wires prior to disconnection when
servicing controls. Wiring errors can cause improper
and dangerous operation.
white
black
(REAR)
MAIN
BURNER
red
red
black
black
VALVE
Regency
®
L900E Direct Vent Gas Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liberty l900e-lp

Table of Contents