Troubleshooting - Procom MN060HBA Owner's Operation And Installation Manual

Blue flame vent-free natural gas space heater
Table of Contents

Advertisement

OBSERVED PROBLEM
Burner(s ) d o e s n o t l i g h t a f t e r
ODS/pilot is lit.
Delayed ignition of burner(s).
Burner backfiring during combustion.
Yellow flame during burner
combustion.
Slight smoke or odor during
initial operation.
Heater produces a whistling noise
when burner is lit.
Heater produces a clicking/ticking
noise just after burner is lit or
shut off.
White powder residue forming within
burner box or on adjacent
walls or furniture.

TROUBLESHOOTING

Continued
POSSIBLE CAUSE
1. Burner orifice is clogged.
2. Burner orifice diameter is too small.
3. Inlet gas pressure is too low.
1. Manifold pressure is too low.
2. Burner orifice is clogged.
1. Burner
orifice
is clogged
damaged.
2. Burner is damaged.
3. Gas regulator is defective.
1. Not enough air.
2. Gas regulator is defective.
3. Inlet gas pressure is too low .
1. Residues from manufacturing
processes
.
1. Turning control knob to HI position
when burner is cold.
2. Air in gas line.
3. Air
passageways
blocked.
4. Dirty or partially clogged burner
orifice.
1. Metal is expanding while heating
or contracting while cooling.
1. When heated the vapors
furniture polish, wax, carpet
cleaners,
etc. turn into white
powder residue.
1 5
1. Clean burner orifice (see Cleaning
and Maintenance Page 13) or
replace burner orifice.
2. Replace burner orifice.
3. Contact local natural gas company.
1. Contact local natural gas company.
2. Clean burner (see Cleaning and
Maintenance Page 13) or replace
burner orifice.
or
1. Clean burner orifice (see Cleaning
and
replace.
2. Contact Dealer or PRO-COM.
3. Replace gas regulator.
1. Check burner for dirt and debris.
If found, clean burner(see Cleaning
And Maintenance Page 13).
2. Replace gas regulator.
3. Contact local natural gas company.
1. Problem will stop after a few hours
of operation.
1. Turn control knob to LO position
and let warm up for a minute.
2. Operate burner until air is removed
from line. Have gas line checked
by local natural gas company.
on
heater
3. Observe
clearances (see Figure 4, Page 7).
4. Clean burner (see Cleaning and
Maintenance Page 13) or replace
burner orifice.
1. This
heaters. if noise
contact qualified service person.
from
1. Turn
furniture
cleaner or similar products.
REMEDY
Maintenance Page 13) or
minimum
installation
is
common with most
is
excessive,
heater
off
when
using
polish,
wax, carpet

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MN060HBA and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Mn100hbaMn100tba

Table of Contents