Product Features - Procom MN060HPA Owner's Operation And Installation Manual

Infrared vent-free natural gas space heater
Table of Contents

Advertisement

SAFETY DEVICE
A standard requirement for all vent-free room
heaters. This heater has a pilot with an Oxygen
Depletion Sensor(ODS) safety shutoff system.
The ODS/pilot shuts off the heater if there is
not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with a piezo ignitor.
This system requires no matches, batteries, or
other sources to light heater.
THERMOSTATIC HEAT
CONTROL ON THERMOSTAT
MODELS
These heaters have a control valve with a
thermostat sensing bulb. This results in the
greatest heater comfort and may result in
lower gas bills.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion.An
unvented room heater productes approximately one (1)
ounce (30ml) of wter for every 1,000 BTU's (.3KW's) of
gas input per hour.
U nv en te d ro om h ea te rs a re r ec om m e nd ed a s
supplemental heat (a room) rather than a primary heat
source (an entire house) .In most supplemental heat
application, the water vapor does not create a problem.
In most applications, the water vapor enhances the low
humidity atmosphere experience during cold weather.

PRODUCT FEATURES

Figure1-Vent-Free Natural Gas Heater
3
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use
latest edition of National Fuel Gas Code ANSI Z223.1,
also known as NFPA 54*.
*Available from :
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02269-9101
UNPACKING
1. Remove heater from carton.
2. Remove all protective
heater for shipment.
3.
Check heater for any shipping damage. If heater
is damaged, promptly inform dealer where you
bought heater.
The following steps will help insure that water vapor
does not become a problem.
1. Be sure the heater is sized properly for the
application, including ample combusion air and
circulation air.
2. If high humidity is experienced, a dehumidifier may
be used to help lower the water vapor content of the
air.
3. Do not use an unvented room heater as the primary
heat source.