6. If heater shuts off, do not relight until you have provided fresh, outside air. If heater keeps shutting off, have it
serviced.
7.
Do not run heater:
Where flammable liquids or vapors are used or stored.
Under dusty conditions.
8. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from
these products may create a white powder residue within burner box or on adjacent walls or furniture.
9. Always run heater with control knob at PILOT/IGN, LOW or HIGH locked positions. Never set control knob be
tween locked positions. Poor combustion and higher levels of carbon monoxide may result.
10. Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect
the room heater and to replace any part of the control system and any gas control which has been under water.
11.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair
heater.
12. Operating heater above elevations of 4,500 feet could cause pilot outage.
13. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.
QUALIFIED INSTALLING AGENCY
Only a qualified agency should install and replace gas piping, gas utilization equipment or accessories, and repair and
equipment servicing.The term "qualified agency" means any individual, firm, corporation, or company that either in
person or through a representative is engaged in and is responsible for:
a) Installing, testing, or replacing gas piping or
b) Connecting, installing, testing, repairing, or servicing equipment; that is experienced in such work; that is familiar
with all precautions required; and that has complied with all the requirement of the authority having jurisdiction.

PRODUCT FEATURES

SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the
heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic piezo control system. This system requires AAA batteries (provided).
2 GAS OPTIONS CAPABLE
Your heater is equipped to operate on either Propane or Natural gas. The heater is shipped from the factory ready for
connecting to Propane. The heater can easily be changed to Natural gas by having your qualified installer follow the
instructions on page 13 and the markings on the heater.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The
National Fuel Gas Code, ANSI Z./ NFPA 5.