Finishing; Mantel And Wall Projections - Quadra-Fire QV32B-A Owner's Manual

Installation and operation
Hide thumbs Also See for QV32B-A:
Table of Contents

Advertisement

13
13

Finishing

A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materials
(i.e., steel studs, concrete board, etc.).
Combustible Mantels
All measurements are in inches.
6
5
4
3
TOP OF HOOD OR FIREPLACE OPENING
Figure 13.1 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Combustible Mantel Legs or Wall Projections
TOP VIEW
5-3/8 IN.
MINIMUM
Note: Clearance from opening
to perpendicular wall.
Figure 13.2 Clearances to Mantel Legs or Wall Projections
(Acceptable on both sides of opening.)
52
CEILING
12
11
10
9
8
7
13
12
11
10
9
8
7
6
5
4
3 IN.
MINIMUM
3 FT. MAXIMUM
Quadra-Fire • QV32B-A, QV36B-A • 2014-900 Rev. U • 1/12
TOP VIEW
Note: Clearance from opening
to perpendicular wall.
Figure 13.3 Wall Projection (Acceptable on one side of opening.)
32
1/2 in.
Figure 13.4 Non-Combustible Zone
3 IN.
MINIMUM
5-3/8 IN.
MINIMUM
UNLIMITED
1/2 in.
SHEETROCK
3-1/2 in.
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE
AIR SPACE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qv36b-a

Table of Contents