1.32 Trouble Shooting; Check Oil Level - Hayter Harrier 41 410E Owner's Handbook Manual

Table of Contents

Advertisement

PROBLEM
Engine will not turn over
Engine smokes
Engine runs then stops
Engine will not start
Engine runs rough
TROUBLE SHOOTING
POSSIBLE FAULT
Engine stop lever released.
Incorrect oil level.
Obstruction under deck.
Battery discharged (412 Only)
Excess oil level.
Air cleaner cartridge oil
soaked or blocked.
Fuel starvation.
Fuel cap vent blocked.
Engine under load.
Fuel starvation.
Engine cold.
Incorrect/contaminated fuel.
Spark plug lead disconnected.
Throttle setting incorrect.
Engine brake not released.
Faulty spark plug.
Battery discharged (412 Only)
Wiring fault.
Spark plug lead becoming
disconnected in use.
Faulty spark plug.
Air cleaner blocked.
Incorrect/contaminated fuel.
REMEDY
Operate engine stop lever.

Check oil level.

Remove obstruction.
Charge battery
Check oil level.
Service air cleaner.
Fill fuel tank.
Clean fuel cap vent.
Raise height of cut.
Fill fuel tank.
Set throttle to 'choke' position.
Drain fuel tank and fill with
correct fuel.
Connect spark plug lead.
Set throttle to 'fast' position.
Operate engine brake lever.
Clean and adjust gap or replace.
Charge battery
Check wiring.
Connect spark plug lead.
Clean and adjust gap or replace.
Service air cleaner.
Drain tank and fill with correct fuel.
1.31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Harrier 41 412eHarrier 41 413e

Table of Contents