Fisher & Paykel RX256DT7X1 Installation Instructions And User Manual page 21

Fisher & paykel side by side refrigerator installation instructions and user guide
Hide thumbs Also See for RX256DT7X1:
Table of Contents

Advertisement

Available languages

Available languages

W
F
ATER
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model UKF8001AXX
Specifications
Service Flow Rate (Maximum) ............................................ 0.78 GPM (2.9 L/min)
Rated Service Life UKF8001AXX-750 (Maximum) ...... 750 gallons /2838 liters
Maximum Operating Temperature .................................... 100° F / 38° C
Minimum Pressure Requirement ....................................... 35 psi / 241 kPA
Minimum Operating Temperature ..................................... 33° F / 1° C
Maximum Operating Pressure ............................................ 120 psi / 827 kPA
Performance Data
USEPA
Parameter
MCL
Challenge Concentration
Chlorine
T & O
Particulate**
USEPA
Parameter
MCL
Turbidity
1 NTU**
Cysts
99.5% Reduction
Asbestos
99% Reduction
Lead at pH 6.5
0.015 mg/L
Lead at pH 8.5
0.015 mg/L
Mercury at pH 6.5
0.002 mg/L
Mercury at pH 8.5
0.002 mg/L
Atrazine
0.003 mg/L
Benzene
0.005 mg/L
Carbofuran
0.04 mg/L
p-Dichlorobenzene
0.075 mg/L
Lindane
0.0002 mg/L
Toxaphene
0.003 mg/L
* Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp. of
68° + 5° F (20° + 3° C)
** Measurement in Particles /ml. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water treatment
needs.
DO NOT use this product where water is
micro bio logic ally unsafe or of unknown quality without
adequate disinfection before or after the system.
System certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK FOR
COMPLIANCE WITH THE STATE AND LOCAL LAWS
AND REGULATIONS.
ILTER
Standard No. 42: Aesthetic Effects
Influent
Influent
Average
2.0 mg/L ± 10%
1.88 mg/L
at least 10,000 particles/ml
5,700,000 #/ml
Standard No. 53: Health Effects
Influent
Challenge
Average
Concentration
11 ± 1 NTU***
Minimum 50,000/L
166,500 #/L
10
10
fibers/L; fibers >10
7
8
micrometers in length
0.15 mg/L + 10%
0.153 mg/L
0.15 mg/L + 10%
0.150 mg/L
.006 mg/L ± 10%
0.006 mg/L
.006 mg/L ± 10%
0.006 mg/L
0.009 mg/L + 10%
0.009 mg/L
0.015 mg/L ± 10%
0.014 mg/L
0.08 mg/L ± 10%
0.081 mg/L
.225 mg/L ± 10%
0.208 mg/L
0.002 mg/L + 10%
0.002 mg/L
0.015 ± 10%
0.015 mg/L
Effluent
Average
Maximum
<0.05136364
0.06 mg/L
mg/L
30,583 #/ml
69,000 #/ml
Effluent
Influent
Average
Maximum
10.7 NTU
0.31 NTU
.049 NTU
< 1 #/L
<1 #/L
155 MF/L
<1 MF/L
<1 MF/L
< .001 mg/L
< .001 mg/L
< .001 mg/L
< .001 mg/L
0.0003 mg/L
0.0005 mg/L
0.0008 mg/L
0.0015 mg/L
< 0.002 mg/L
0.002 mg/L
0.0006 mg/L
0.0011 mg/L
< 0.001 mg/L
<0.001 mg/L
< 0.0005 mg/L
<0.0005 mg/L
0.000 mg/L
<0.0001 mg/L
< 0.001 mg/L
< 0.001 mg/L
Tested and certified by NSF International against ANSI/NSF Standards 42 &
53 in models UKF8001AXX-750 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
Particulate Reduction Class 1
The retractable water filtration system uses a UKF8001AXX
replacement cartridge. Timely replacement of filter cartridge
is essential for performance satisfaction from this filtration
system. Please refer to the applicable section of your Use &
Care Guide for general operation, maintenance requirements
and troubleshooting. Suggested retail price of replacement
water filter is $39.99.
This system has been tested according to ANSI/NSF 42
and 53 for reduction of the substance listed above. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system,
as specified in ANSI/NSF 42 and 53.
1000 Apollo Road
Eagan, Minnesota 55121-2240
651.450.4913
EPA EST #35917-MN-1
100834/B
% Reduction
Average
Minimum
>97.26%
96.84%
99.52%
98.94%
% Reduction
Average
Minimum
97.09%
95.20%
> 99.99%
> 99.99%
> 99.99%
> 99.99%
> 99.35%
> 99.29%
> 99.33%
> 99.29%
95.70%
90.91%
86.22%
75.93%
76.99%
75.31%
95.71%
92.14%
98.74%
98.46%
99.76%
99.74%
98.72%
96.50%
92.97%
91.67%
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Benzene,
Carbofuran, p-Dichlorobenzene,
Mercury & Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
Min. Required
Reduction
50%
85%
Min. Required
Reduction
0.5 NTU
> 99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
18

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents

Save PDF