Installation
Instructions
CONNECTING
A GAS DRYER {cont.)
TEST FOR LEAKS
A WARNING
-
Never use an open
flame to test for gas leaks.
Check all connections
for leaks with soapy solution
or equivalent.
Apply a soap solution. The leak test solution must
not contain ammonia,
which could cause damage
to the brass fittings.
If leaks are found, close the valve, retighten the joint
and repeat the soap test.
Open Gas
Valve
ELECTRICAL CONNECTION
INFORMATION
FOR GAS DRYERS
A WARNING
-
To reduce the risk of
fire, electric
shock and personal
injurg:
. Do not use an extension cord or an adapter
plug
with this appliance.
. The dryer must be electrically
grounded
in
accordance
with local codes and ordinances,
or
in the absence of local codes, in accordance
with
the NATIONAL ELECTRICALCODE, ANSI/NFPA
NO. 70.
ELECTRICAL REQUIREMENTS
FOR GAS DRYERS
This appliance
must be supplied with &20V, 60Hz,
and connected
to a properly grounded
branch
circuit, protected
by a 15- or 20-amp
circuit breaker
or time-delay
fuse.
If electrical supply provided does not meet the
above specifications,
it is recommended
that a
licensed electrician
install an approved
outlet.
A WARNING - This
dryer
is
equipped with a three-prong
(grounding)
plug for
your protection
against shock hazard and should
be plugged directly into a properly grounded
three-prong
receptacle.
Do not cut or remove
the grounding
terminal from this plug.
Ensure proper
Ill
I! /1
ground exists
.....
before use.