Switch 6: VR1 Potentiometer Adjustment mode
Selects the function adjusted by VR1. If DSW6 is Off, VR1
adjusts the pitch offset value over a range of +/- 3.75 mm.
When DSW6 is On, VR1 adjusts the print darkness range.
Switch 7: DATA Dump
When ON, the printer will print out the hex value for each
character received. When OFF, the printer will accept and
process the data stream in a normal fashion.
Switch 8: Interface Board selection
This switch lets you choose whether to use the factory
installed interface board connectors, or the user-installable
Extended Interface board.
If not extended interface board is detected, switching
DSW8 to Off will not affect the use of the built-in interface.
CT4i Series Operator Manual
Unit 4: Printer Configuration
4-6
DSW6
Mode
Off
Pitch Offset
On
Print Darkness
Configuration Switch
ON
OFF
1
2
3
4
5
DSW7
Mode
Off
DISABLED
On
ENABLED
Configuration Switch
ON
OFF
1
2
3
4
5
DSW8
Mode
Off
Use extended
interface
On
Use internal
interface
Configuration Switch
ON
OFF
6
7
8
6
7
8