Technical Specifications Aw250Dmb; Amplifier Section; Output Impedance; Rated Output Power - ELECTROCOMPANIET AW-250 Owner's Manual

Dual mono balanced power amplifier
Table of Contents

Advertisement

Technical Specifications AW250DMB :

The following technical data were measured on randomised test objects and are typical
data. All measurements are made with the following equipment:
Distortion analyser: Tektronix AA501
Oscilloscope:
Oscillator:
Frequency counter: Rascal 9838
Phase meter:

Amplifier section

Main voltage 120 V / 240 V. Clipping point of the amplifier is set to a level where total
harmonic distortion (THD) is 0.2 %.
Output Impedance (20 Hz - 20 kHz)
RCA (single) input impedance
XLR (balanced) input impedance
Input sensitivity for rated output
Max. peak current
THD (measured at 1 kHz half power, 8 Ohm)
THD (measured at 1 kHz -1 dB, 8 Ohm)
Noise (measured with both inputs shorted)
400 Hz - 30 kHz :
10 Hz - 30 kHz :

Rated output power

10 % change in line voltage will give app. 20 % change in output power.
8 Ohm 2 x 250 W
4 Ohm 2 x 380 W
2 Ohm 2 x 625 W
1 Ohm 2 x 1100 W
Power consumption (no load or signal) 230 W
Dimensions
Width 483 mm / 19 inches
Depth 450 mm / 17 inches
Height 210 mm / 8.2 inches
Weight39 kg. / 85.8 lbs.
The manufacturer reserves the right to alter these specifications without further notice.
Tektronix 468
Tektronix SG505
Hewlett Packard 3575A
< 0,008 Ohm
220 kOhm
110 kOhm
1 V
> 100 A
< 0,001 %
< 0,001 %
90 µV
100 µV

Advertisement