"A" group: Standard Functions

Func.
Code
A001/
Frequency source setting
A201
00 Keypad potentiometer
01 Control terminal
02 Function F_01 setting
03 RS485 Modbus communication
10 Calculate function output
A002/
Run command source setting
A202
01 Input terminal FW or RV (assignable)
02 RUN key on the keypad
03 RS485 Modbus communication
A003/
Base frequency setting
A203
A004/
Maximum frequency setting
A204
A005
[AT] selection
02 Select [O] or POT by [AT] terminal input
03 Select [OI] or POT by [AT] terminal input
04 [O] input only
A005
AT input
Active
Not assigned [AT] is the same as [AT]=OFF.
A011
O-L input active range start frequency
A012
O-L input active range end frequency
A013
O-L input active range start voltage
A014
O-L input active range end voltage
A015
O-L input start frequency enable
00 Use A011 (starting value)
A016
External frequency filter time constant
A020/
Multi-speed frequency setting
A220
A021~
Multi-speed frequency settings
A035
(for both motors)
A038
Jog frequency setting
A039
Jog stop mode
00 Free-run stop, jogging disabled during motor run
01 Controlled deceleration, jogging disabled during
motor run
02 DC braking to stop, jogging disabled during motor
run
A041/
Torque boost method selection
A241
00 Manual torque boost
01 Automatic torque boost
A042/
Manual torque boost value
A242
A043/
Manual torque boost frequency adjustment
A243
A044/
V/f characteristic curve selection
A244
00 V/f constant torque
01 V/f variable torque
06 V/f variable torque1
Name / Description
05 [OI] input ony
02
03
OFF
ON
OFF
[O]
POT
[OI]
- 13 -
04
ON
OFF
ON
POT
[O]
01 Use 0Hz
10.0(A043)/
Default
Set
-FE/-FU
value
01/00
01/00
50/60
50/60
02
05
OFF
ON
[OI]
0.0
0.0
0.
100.
01
8.
0.0
0.0
1.0
00
00
1.8(A042)/
0.0(A242)
0.0(A243)
00