Analog Input Configuration

The following tables show the parameter settings required for various
analog input signal types.
A005
AT input
OFF
Active
[O]
If [AT] is not assigned to any intelligent input terminal, it means
AT=OFF in above table.
Note:
Analog input O and OI cannot be used at the same time.
Analog Output Function Listing
The following table shows all three functions available for assignment to
the analog output terminal:
Terminal [AM], option set by C028
Option
Function
Code
Name
00
Output
frequency
01
Output
current
02
03
ON
OFF
POT
[OI]
Description
Actual
motor
represented by PWM
signal
Motor current (% of
maximum rated output
current),
by PWM signal
- 21 -
04
ON
OFF
ON
POT
[O]
speed,
0 to max. freq. in Hz
0 to 200%
represented
05
OFF
ON
[OI]
Corresponding
Signal Range