Hitachi X200 Series Quick Reference Manual page 18

Hide thumbs Also See for X200 Series:
Table of Contents

Advertisement

Func.
Code
B083
Carrier frequency setting
B084
Initialization mode (parameter or trip history)
00 Trip history clear
01 Parameter initialization
02 Trip history clear and parameter initialization
B085
Country code for initialization
00 Japan version
02 US version
B086
Frequency scaling conversion factor
B087
STOP key enable
00 Enable
B088
Restart mode after FRS
00 Restart from 0Hz
01 Restart with frequency pull-in
B089
Data select for digital operator OPE-J
01 Output frequency (d001)
02 Output current (d002)
03 Motor direction (d003)
04 PID PV feedback (d004)
05 Input status for input terminals (d005)
06 Output status for output terminals (d006)
07 Scaled output frequency (d007)
B091
Stop mode selection
00 DEC (decelerates and stop)
01 FRS (free-run to stop)
B092
Cooling fan control
00 Fan is always ON
01 Fan is ON during run, OFF during stop (5
minutes delay from ON to OFF)
02 Fan is temperature controlled
B130
Over-voltage LADSTOP enable
00 Disable
B131
Over-voltage LADSTOP level
B133
DC bus AVR selection
00 Disable
B134
Threshold voltage of DC bus AVR setting
B140
Over-current trip suppression
00 Disable
B150
Automatic carrier control
00 Disable
B151
Selection of RDY function
Name / Description
01 Europe version
01 Disable
01 Enable
01 Enable
01 Enable
01 Enable
- 17 -
Default
Set
-FE/FU
value
3.0
00
01/02
1.0
00
00
01
00
00
00
380,760
00
380,760
00
00
00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents