Jumper connecting
Terminals PD and P
When not using the DCL,
do not remove the jumper
from terminals PD and P.
[Method of enabling/disabling the EMC filter function]
Enabling the EMC filter
R
S
T
(L1)
(L2)
(L3)
Jumper connecting terminals
PD and P
Terminal layout
Ground terminal with
jumper (shaded in the
figure) to enable/disable the
EMC filter function
Disabling the EMC filter
(factory setting)
PD
P
N
(+1)
(+)
(-)
2 - 15
Chapter 2 Installation and Wiring
R0
T0
Charge lump
U
V
W
(T1)
(T2)
(T3)
Inverter model
L700-750LFF
R0 and T0: M4
Ground terminal: M8
Other terminals: M10
L700-900-1600HFF
R0 and T0:M4
Ground terminal:M8
Other terminal:M10